MP 6.01.18 Scintimammography and Gamma Imaging of the Breast and Axilla

Medical Policy    
Section
Radiology 
Original Policy Date
1/30/98
Last Review Status/Date
Reviewed with literature search/5:2014
Issue
5:2014
  Return to Medical Policy Index

Disclaimer

Our medical policies are designed for informational purposes only and are not an authorization, or an explanation of benefits, or a contract.  Receipt of benefits is subject to satisfaction of all terms and conditions of the coverage.  Medical technology is constantly changing, and we reserve the right to review and update our policies periodically. 


Description

Scintimammography refers to the use of radiotracers with nuclear medicine imaging as a diagnostic tool for abnormalities of the breast. Breast-specific gamma imaging (BSGI), or molecular breast imaging (MBI), refer to specific types of imaging machines that are used in conjunction with scintimammography in order to improve diagnostic performance.

Scintimammography is a diagnostic modality using radiopharmaceuticals to detect tumors of the breast. After injection of a radiopharmaceutical, the breast is evaluated with planar imaging. Scintimammography is performed with the patient lying prone and the camera positioned laterally, which increases the distance between the breast and the camera. Scintimammography using conventional imaging modalities has relatively poor sensitivity in detecting smaller lesions (e.g., smaller than 15 mm), because of the relatively poor resolution of conventional gamma cameras in imaging the breast. Interest in this approach has increased in recent years with the development of breast-specific gamma imaging (BSGI) and, even more recently, molecular breast imaging (MBI). Breast-specific gamma cameras acquire images while the patient is seated in a position similar to that in mammography, and the breast is lightly compressed. The detector head(s) is immediately next to the breast, increasing resolution, and the images can be compared with the mammographic images. Breast-specific gamma imaging and molecular breast imaging differ primarily in the type and number of detectors used (multi-crystal arrays of cesium iodide or sodium iodide versus semiconductor materials, such as cadmium zinc telluride, respectively). In some configurations, a detector is placed on each side of the breast, and they lightly compress it. The maximum distance between the detector and the breast is therefore from the surface to the midpoint of the breast. MBI systems can achieve greater resolution and smaller pixel size. Much of the research on BSGI and MBI has been conducted at the Mayo Clinic. The radiotracer usually utilized is technetium Tc99m sestamibi. MBI imaging takes approximately 40 minutes. (1)

BSGI and MBI have been suggested for a variety of applications. In a 2010 practice guideline for breast scintigraphy with breast specific gamma cameras,(2) the Society of Nuclear Medicine provided a list of common uses, as follows:

  1. Among patients with recently detected breast malignancy, initial staging; detecting multicentric, multifocal, or bilateral disease; and assessing response to neoadjuvant chemotherapy.
  2. Among patients at high risk for malignancy, evaluating suspected recurrence or using it when a mammogram is limited or a previous malignancy was occult on mammogram.
  3. Among patients with indeterminate breast abnormalities and remaining diagnostic concerns: to evaluate lesions identified by other breast imaging techniques, palpable or nonpalpable; to aid in biopsy targeting, and other settings (eg, diffuse or multiple clusters of microcalcifications, unexplained architectural distortion)
  4. Among patients with technically difficult breast imaging, such as radiodense breast tissue or implants, free silicone, or paraffin injections.
  5. Among patients for whom breast magnetic resonance imaging (MRI) is indicated but contraindicated, e.g., patients with implanted pacemakers or pumps, or as an alternative for patients who meet MRI screening criteria, such as BRCA1/BRCA2 mutations.
  6. Among patients undergoing preoperative chemotherapy, for monitoring tumor response in order to determine the impact of therapy of plan for residual disease.

The guideline acknowledged other efforts, such as the American College of Radiology’s Appropriateness Criteria(3-5) and the American College of Surgeons’ Consensus Conference III.(6)

Radiopharmaceuticals
The primary radiopharmaceutical used with BSGI or MBI is technetium Tc-99m sestamibi (marketed by Draxis Specialty Pharmaceuticals Inc., Cardinal Health 414, LLC, Mallinckrodt Inc., and Pharmalucence Inc.). The product label states that technetium Tc-99m sestamibi is “indicated for planar imaging as a second-line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass. Technetium Tc-99m sestamibi is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.”(7)

Technetium TC-99m tetrofosmin (Myoview™), a gamma-emitter used in some BSGI studies,(8,9) is U.S. Food and Drug Administration (FDA)-approved only for cardiac imaging.(10)

Gamma Cameras
Several scintillation (gamma) cameras have general 510(k) marketing clearance from FDA, which states that they are cleared for “measuring and imaging the distribution of radionuclides in the human body by means of photon detection.”(11) Two examples of gamma cameras used in BSGI or MBI (FDA Product Code IYX) are Dilon 6800® (Dilon Technologies, Newport News, VA) and LumaGEM™ (Gamma Medica™ Instruments, Northridge, CA).

Radiation Exposure
The radiation dose associated with BSGI is substantial for diagnostic breast imaging modalities. According to Appropriateness Criteria from the ACR, the radiation dose from BSGI is 10 to 30 mSv, which is 15 to 30 times higher than the dose from a digital mammogram.(3) According to ACR Appropriateness Criteria, at these levels BSGI is not indicated for breast cancer screening.

According to another study,(12) the radiation dose to the breast from the 20 mCi (740 MBq) dose of technetium Tc-99m sestamibi used for BSGI at 1 center is 0.13 rad or 1.3 mGy, less than the 0.75 rad the authors reported for mammography, except that the dose is given to the entire body. The authors asserted that this dose poses an “extremely low risk of harmful effects to the patient” but that it should be reduced by a factor of 5 to 10 if BSGI were to be used as a regular screening technique. The authors also estimated that the cost of BSGI is 3 to 4 times that of mammography.

Another article published online in August 2010 calculated mean glandular doses, and from those, lifetime attributable risks (LAR) of cancer, due to film mammography, digital mammography, BSGI, and positron emission mammography (PEM).(13) The author, who is a consultant to GE Healthcare and a member of the medical advisory boards of Koning (manufacturer of dedicated breast computed tomography [CT]) and Bracco (MR contrast agents), used group risk estimates from the Biological Effects of Ionizing Radiation (BEIR) VII report(14) to assess the risk of radiation-induced cancer and mortality from breast imaging studies. For a patient with average-sized breasts (compressed thickness during mammography of 5.3 cm per breast), estimated LARs of cancer at age 40 were:

  • 5 per 100,000 for digital mammography (breast cancer only),
  • 7 per 100,000 for screen film mammography (breast cancer only),
  • 55-82 per 100,000 for BSGI (depending on the dose of technetium Tc-99m sestamibi), and
  • 75 for 100,000 for PEM.

Corresponding lifetime attributable risks of cancer mortality at age 40 were:

  • 1.3 per 100,000 for digital mammography (breast cancer only),
  • 1.7 per 100,000 for screen film mammography (breast cancer only),
  • 26-39 per 100,000 for BSGI, and
  • 31 for 100,000 for PEM.

A major difference in the impact of radiation between mammography, on the one hand, and BSGI or PEM, on the other, is that for  mammography, the substantial radiation dose is limited to the breast. With BSGI and PEM, all organs are irradiated, increasing the risks associated with BSGI and PEM. Researchers at the Mayo Clinic have investigated lower dose versions of MBI,(15) and 2 small studies (NCT01653964, NCT01285440; total N=232) are ongoing. (A larger study of reduced-dose MBI in 2000 women with dense breast tissue on mammography and increased cancer risk has been suspended [NCT01723124]). Mayo Clinic researchers assert that this new approach will “make MBI comparable with screening mammography in terms of radiation exposure.”(1) It is unclear whether this statement refers to
breast exposure or whole body exposure.

Notes: The term “molecular breast imaging” is used in different ways, sometimes for any type of breast imaging involving molecular imaging, including PEM, and sometimes limited to imaging with a type of breast-specific gamma camera, as used in this report. Use of single positron emission computed tomography (SPECT) and positron emission tomography (PET) of the breast are not covered in this policy.


Policy

Scintimammography, breast-specific gamma imaging (BSGI), and molecular breast imaging (MBI) are considered investigational in all applications, including but not limited to their use as an adjunct to mammography or in staging the axillary lymph nodes.

Preoperative or intraoperative sentinel lymph node detection using handheld or mounted mobile gamma cameras is considered investigational.


Policy Guidelines

The most commonly used radiopharmaceutical used in for BSGI or MBI is technetium Tc 99m sestamibi (marketed by Draxis Specialty Pharmaceuticals Inc., Cardinal Health 414, LLC, Mallinckrodt Inc., and Pharmalucence, Inc.). There is a specific HCPCS code for this radiopharmaceutical:

A9500: Technetium Tc-99m sestamibi, diagnostic, per study dose, up to 40 millicuries. 


Benefit Application

BlueCard/National Account Issues

State or federal mandates (e.g., FEP) may dictate that all FDA-approved devices may not be considered investigational and thus these devices may be assessed only on the basis of their medical necessity. 


Rationale

This policy was created in January 1998 and updated periodically with literature review. The current version is based on a 2013 TEC Assessment (currently in press)(16) and a literature review through April 9, 2014.

2013 TEC Asessment

Mammography is the main screening modality for breast cancer, despite its limitations in terms of less than ideal sensitivity and specificity. Limitations of mammography are particularly an issue for women at high risk of breast cancer, for whom cancer risk exceeds the inconvenience of more frequent screening starting at a younger age with more frequent false positive results. Furthermore, the sensitivity of
mammography is lower in women with radiographically dense breasts, which is more common among younger women. The clinical utility of adjunctive screening tests, such as scintimammography or magnetic resonance imaging (MRI), is primarily in the evaluation of women with inconclusive results on mammography. A biopsy is generally performed on a breast lesion if imaging cannot rule out malignancy with certainty. Therefore, adjunctive tests will be most useful in women with inconclusive mammograms if they have a high negative predictive value (NPV), and can preclude the need for biopsy. Additional imaging for asymptomatic women who have dense breasts and negative mammogram has been suggested, but the best approach is subject to debate (see TEC Special Report: Screening Asymptomatic Women with Dense Breasts and Normal Mammograms for Breast Cancer).(17)

The TEC Assessment reviewed evidence for women undergoing breast cancer screening, including those with dense breasts or at high risk of breast cancer, and in women who had suspicious physical or imaging findings. Retrospective studies included women with a mix of indications. For all other indications, evidence was insufficient. A few studies reported on change in patient management after imaging, but there were insufficient data to determine whether these changes led to improvement in health outcomes (eg, (18)).

BSGI for Women With Breast Cancer Risk Factors and/or Normal Mammograms

An early step in evaluating a new imaging modality for patients who may have breast cancer is to determine whether the modality can detect breast cancer or related diagnoses in women known to have the disease. However, studies of diagnostic performance in this population may be affected by disease spectrum (spectrum effect), among other possible issues. Showing that the modality can detect breast cancer, particularly smaller lesions and types that are more difficult to detect, is important, but not sufficient to demonstrate the true diagnostic performance of a test, which may vary with tumor size and characteristics, etc. Available studies are limited by the retrospective nature of most; by small sample sizes; and by patient populations with mixed indications for imaging (eg, (19-22)).

Several prospective studies assessed breast specific gamma imaging (BSGI) in women at high risk for breast cancer and/or with normal mammograms. Rhodes et al (2011) compared BSGI, mammography, and the combination of the 2 modalities in 936 asymptomatic women with heterogeneously or extremely dense breasts on prior mammogram, as well as additional risk factors.(23) Eleven (1.2%) of 936 women
had cancer. The sample included women with dense breasts and other cancer risk factors, including women with BRCA mutations and women with a personal history of breast cancer. Risk in these different populations varies substantially. Overall sensitivity was 82% (95% confidence interval [CI], 52 to 95) for BSGI, 27% (95% CI, 10 to 57) for mammography, and 91% (95% CI, 62 to 98) for both combined. Specificity was 93% (95% CI, 91 to 94) for BSGI, 91% (95% CI, 89 to 93) for mammography, and 85% (95% CI, 83 to 87) for both (sensitivity and specificity for BSGI vs mammography, both p=0.07). The number of breast cancers diagnosed per number of biopsies performed was 28% for BSGI and 18% for mammography.

Brem et al (2005) used a breast-specific gamma camera to evaluate 94 women considered at high risk of breast cancer, despite normal mammographic findings.(24) High risk was defined as a 5-year breast cancer risk of 1.66%, as determined by the Gail model. Of 94 women in the study, 35 (37%) had a prior history of some type of breast cancer or atypical hyperplasia. Sixteen women (17%) had abnormal scintimammograms. Follow-up ultrasound in 11 of these identified a hypoechoic lesion that was biopsied. The 5 remaining patients had normal ultrasound results and were followed up with a repeat scintimammogram at 6 months, which was normal in all 5. Among the 11 women who underwent ultrasound-guided biopsy, 2 invasive cancers (12%) were identified. Sensitivity of BSGI was 100% (95% CI, 22 to 100), and specificity was 85%. The study was limited by the small number of cancers detected.

In a retrospective study of 341 women with biopsy-proven breast cancer, Rechtman et al (2014) determined the sensitivity of BSGI in dense versus nondense breasts.(25) Mean patient age was 55 years (range, 28-89). All patients underwent preoperative BSGI and mammography; women with Breast Imaging Reporting and Data System (BI-RADS) density 1 or 2 were classified as having nondense breasts, and those with BI-RADS density 3 or 4 were classified as having dense breasts. Of 347 biopsy-proven breast cancers, BSGI was positive in 331 (overall sensitivity, 95%). In women with dense versus nondense breasts, BSGI sensitivity for detection of mammographically occult breast cancer did not differ statistically (97% vs 95%, respectively; x², p=0.102).

Although the use of BSGI or MBI has been proposed for women at high risk of breast cancer, there is controversy and speculation over whether some women, such as those with BRCA mutations, have a heightened radiosensitivity.(26,27) If women with BRCA mutations are more radiosensitive than the general population, the studies previously cited (see Background) may underestimate the risks of breast imaging with ionizing radiation (ie, mammography, BSGI, molecular breast imaging (MBI), positron emission mammography (PEM), single positron emission computed tomography/computed tomography (SPECT/CT), breast-specific CT, and tomosynthesis) in these women. In contrast, ultrasound and MRI do not involve the use of radiation. More research will be needed to resolve this issue. Also, the risk associated with radiation exposure will be greater for women at high risk of breast cancer, whether or not they are more radiosensitive, because they start screening at a younger age when the risks associated with radiation exposure are greater.

Section Summary
There is scant evidence on the use of BSGI for screening women at elevated risk of breast cancer or in women with factors that limit the sensitivity of mammography. Furthermore, the relatively high radiation dose currently associated with BSGI has prompted the American College of Radiology to recommend against the use of BSGI for screening. Therefore, consideration of the potential use of BSGI for screening women with dense breasts or at high risk of breast cancer should await the development of a lower-dose regimen, and if warranted, larger, higher quality studies with study populations representative of patients encountered in clinical practice. In addition, a large, high-quality head-to-head comparison of BSGI and MRI would be needed, especially for women at high risk of breast cancer, because MRI, alternated with
mammography, is currently the recommended screening technique.

BSGI for Women With Indeterminate or Suspicious Lesions

Several prospective studies have addressed BSGI in women who have indeterminate or suspicious lesions. Spanu et al (2012) assessed the clinical impact of BSGI in a prospective study of 467 women who had suspicious lesions on physical examination, MRI, ultrasound, or mammogram.(28) Histopathology reports were obtained in all cases. BSGI results were true positive in 408/420 breast cancer patients (sensitivity, 97%), including the detection of multifocal, multicentric disease and bilateral disease, and were false negative in 12 breast cancer patients. BSGI results were true negative in 40/47 patients with benign lesions (specificity, 85%). The authors calculated that BSGI provided additional value compared with mammography in 141 (30%) of 467 patients: 108 who had breast cancer and 33 with benign lesions.

Another study by Spanu et al (2009) evaluated BSGI compared with (SPECT in 157 women with suspicious breast lesions at clinical examination and/or mammography or ultrasound.(29) Histopathologic reports were obtained in all cases. Outcomes were calculated on a per lesion basis. Sensitivity was significantly higher for BSGI compared with SPECT (96% vs 91%, p<0.01), as was diagnostic accuracy (94% vs 90%, p<0.01). Specificity was identical for both imaging modalities (88%). In a similar 2007 study by Spanu et al, BSGI performance was compared with SPECT in 85 patients scheduled to undergo biopsies.(30) Histopathologic findings were obtained in all cases. On a per lesion basis (90 malignant, 12 benign), BSGI sensitivity (97%) and accuracy (96%) were higher compared with SPECT (92% and 92%, respectively), but the differences were not statistically different. Specificity was 92% for both imaging modalities.

In a 2008 study by Hruska et al, 150 patients with BI-RADS classification 4 or 5 lesions smaller than 2 cm identified on mammography or ultrasound who were scheduled for biopsy underwent scintimammography using a dual-head, breast-specific gamma camera.(31) Results from 3 blinded readers were averaged. In 88 patients, 128 cancers were found. The per-lesion sensitivity with the dual-head camera was 90% (115/128) for all lesions and 82% (50/61) for lesions 1 cm or smaller. Overall, MBI specificity (by patient) was 69%. The proportion of patients with cancer in this study was higher than might be expected in a screening population with suspicios lesions on mammography. In selecting patients, preference was given to those who had a high suspicion of cancer or were likely to have multifocal or multicentric
disease.

Spanu et al (2008) evaluated 145 consecutive patients scheduled for breast biopsy.(32) With an 86% prevalence of disease, sensitivity of BSGI was 98% per patient (100% for tumors >10 mm, 91% for tumors ≤10 mm). Per-lesion specificity was 86%. Four cancers were missed, 3 of which were detected by mammography. The authors suggested using BSGI for surgical planning or to avoid biopsy, but the NPV of 83% was not high enough to forgo biopsy.

Brem et al (2007) compared BSGI and MRI in 23 women with 33 indeterminate lesions.(33) Eight patients had 9 pathologically confirmed cancers. BSGI demonstrated a significantly greater specificity (71% [95% CI, 49 to 87]) than MRI (25% [95% CI, 11 to 47]; p<0.05) and comparable sensitivity (BSGI, 89% [95% CI, 51 to 99] vs MRI, 100% [95% CI, 63 to 100]), positive predictive value (PPV; BSGI, 53% [95% CI, 27 to 78] vs MRI, 33% [95% CI, 17 to 54]), and NPV (BSGI, 94% [95% CI, 71 to 100] vs MRI, 100% [95% CI, 52 to 100]). The authors noted that the 100% sensitivity and 25% specificity of MRI likely was due to the small number of cancers in the study.

In 2014, Tan et al assessed the diagnostic accuracy of dual-phase (at 10-15 minutes and at 90-120 minutes) BSGI in 76 women at a single institution in China who had suspicious breast masses.(34) On pathologic review, 54 (59%) of 92 tumors were malignant and 38 (41%) were benign. Using receiver operating characteristic-determined cut points for visual and semiquantitative interpretation, sensitivity and specificity were maximized when a combination of visual and early phase semiquantitative interpretation was used (85% and 92%, respectively), compared with either analysis or delayed phase semiquantitative analysis alone.

Section Summary
The value of BSGI in evaluating indeterminate or suspicious lesions must be compared with other modalities that would be used, such as spot views for diagnostic mammography. Given the relative ease and diagnostic accuracy of the criterion standard of biopsy, coupled with the adverse consequences of missing a breast cancer, the NPV of BSGI would have to be extremely high to alter treatment decisions. Because NPV is partially determined by disease prevalence, NPV will be lower in a population of patients with mammographic abnormalities highly suggestive of breast cancer than in a population of patients with mammographic abnormalities not suggestive of breast cancer. Therefore, any clinical utility of BSGI as an adjunct to mammography would vary according to the type of mammographic abnormalities included in
the studies.

Ductal Carcinoma In Situ (DCIS)

Kim et al (2013) compared BSGI with dynamic contrast-enhanced MRI in 35 women who had pathologically diagnosed DCIS.(35) Mean patient age was 48 years (range, 26-69). All patients underwent both BSGI and MRI. Overall sensitivity of BSGI and MRI were 69% and 91%, respectively. In 18 women who had microcalcifications on mammography, sensitivity of BSGI and MRI were 83% and 94%, respectively. In 17 women who had no microcalcifications on mammography, sensitivity of BSGI and MRI were 53% and 88%, respectively.

Women with Breast Cancer

Detection of Axillary Metastases
Regarding the use of scintimammography to detect axillary metastases, a review of studies published between 1994 and 1998 showed a sensitivity of 77% and specificity of 89%.(36) More recent studies using different radiopharmaceuticals have shown sensitivities in the high 80% to 90% range.(37,38) A 2011 meta-analysis reviewed 45 studies of scintimammography and also reported sensitivities and specificities in this range, with summary estimates for sensitivity of 83% (95% CI, 82 to 84) and for specificity of 85% (95% CI, 83 to 86).(39) The test still is not accurate enough to replace surgical nodal dissection. No studies have examined patient outcomes comparing the strategy of using scintimammography to aid in decision making regarding nodal dissection versus proceeding directly to nodal dissection.

Bricou et al (2013) reviewed studies of recently-developed mobile gamma cameras for use during breast cancer surgery and/or sentinel lymph node (SLN) biopsy.(40) In this procedure, lymphatic drainage of radioactive colloid injected preoperatively in or around the tumor site is imaged. The review included clinical studies published between January 2000 and March 2012. Thirteen studies of 8 different gamma cameras, both hand-held and arm-mounted, were identified. For preoperative SLN detection, 3 studies (total N=245) reported the comparative accuracy compared with standard lymphoscintigraphy. One study (n=88) reported a sensitivity of mobile gamma cameras that was worse than standard lymphoscintigraphy, study (n=19) reported a better sensitivity, and the third study (n=138) reported noninferiority to standard lymphoscintigraphy. A potential bias in one study was performance of gamma imaging after lymphoscintigraphy, permitting longer migration of the radiotracer. For intraoperative SLN detection, 7 studies (total N=264) also reported mixed results.

Detection of Residual Tumor After Neoadjuvant Therapy
In a single-center, retrospective study, Lee et al (2014) evaluated BSGI detection of residual tumor after neoadjuvant chemotherapy (primarily anthracycline and taxane-based) in 122 women who had pathologically-confirmed invasive breast cancer.(41) Mean patient age was 46 years (range 29-71). All patients underwent BSGI and dynamic contrast-enhanced breast MRI after completing neoadjuvant therapy. Surgeons consulted BSGI and MRI for surgical planning, ie, either breast-conserving therapy (64%) or mastectomy (36%). Of 122 patients, 104 (85%) had residual disease by pathologic review. BSGI sensitivity was 74%, specificity was 72%, NPV was 33%, and PPV was 94%. Sensitivity of BSGI varied with cellularity and size of residual tumor (greater sensitivity with greater cellularity and greater size).

Surgical Planning for Breast-Conserving Therapy
Edwards et al (2013) retrospectively assessed changes in surgical management of 218 women who had breast cancer and were eligible for breast-conserving therapy.(42) All patients had undergone preoperative BSGI or breast MRI. Twelve percent of patients who had BSGI and 29% of those who had MRI changed to mastectomy. On pathologic review, no patient who underwent mastectomy was eligible for breast-conserving therapy. Of patients who received breast-conserving therapy, 15% of those who had BSGI and 19% of those who had MRI required a single re-excision because of positive surgical margins, and 14% and 6%, respectively, required mastectomy. Based on this retrospective study, clinical utility of BSGI for guiding surgical decision making in breast cancer patients appears limited.

Section Summary

For detection of axillary metastases, accuracy of scinitimammography is insufficient to preclude nodal dissection. Clinical utility studies of scinitimammography to guide decision making in this setting are lacking. Mobile gamma cameras for preoperative or intraoperative sentinel lymph node detection are in development. Current evidence comprises small studies with inconsistent results; improved sentinel lymph node detection in comparison with standard gamma probes has not been consistently shown.

Based on single retrospective studies, clinical utility of BSGI for detecting residual tumor after neoadjuvant chemotherapy or for guiding surgical decision making in breast cancer patients appears limited.

Retrospective Studies of BSGI for Women with a Mixed Set of Indications

Several retrospective studies have examined BSGI in women with mixed indications. Brem et al (2008) examined BSGI in a retrospective study of 146 consecutive patients who had a mixed set of indications, including palpable lesions with no mammographic correlation, diagnosis of multicentricity or multifocality in women with known breast cancer, and screening for women at high risk of breast cancer.(43) The analysis was performed per lesion (n=167), not per patient. Eighty-three lesions were malignant (50%). Overall sensitivity of BSGI was 96% (95% CI, 92 to 99), and specificity was 60% (95% CI, 49 to 70). PPV was 69% (95% CI, 60 to 78), and NPV was 94% (95% CI, 88 to 99). The performance of BSGI in particular for detecting smaller tumors requires further investigation. As the authors noted, additional larger studies are needed to confirm or modify these findings.

Park et al (2013) compared BSGI performed shortly after injection of the radiotracer with dual-phase imaging, in which BSGI was repeated 1 hour after the injection.(44) The assumption was that technetium Tc-99m sestamibi uptake might persist on delayed images for malignant lesions, but for benign conditions it would not, thereby reducing false positive results. The study sample comprised 76 women (mean age,
49 years, range 33-61) undergoing evaluation for a palpable lesion or for a diagnosis of multicentricity and/or multifocality in women with biopsy-proven breast cancer, women being screened for breast cancer, or women with multiple lesions detected by mammography or ultrasound in which BSGI was used to determine an appropriate biopsy site. Thirteen women had breast cancer. Comparing single-phase and
dual-phase BSGI, sensitivity was 77% and 69%, respectively (p=1.0); specificity was 83% and 95%, respectively (p=0.008). Thus, dual-phase imaging appeared to increase specificity without a significant effect on sensitivity. However, as the authors noted, the sample size was small. In a subsequent retrospective study by Park et al (2014), diagnostic accuracy of BSGI was increased when both visual and semiquantitative readings (normalized for tracer uptake in the unaffected contralateral breast [background uptake]) were employed compared with visual analysis alone.(45)

Weigert et al (2012) reported data from a retrospective multicenter patient registry.(46) This study analyzed 1042 patients drawn from 2004 patients in the registry. Women included in the study had BSGI imaging, pathologic diagnosis by biopsy, and at least 6 months of follow-up. BSGI had been recommended for patients with at least 2 of the following indications: equivocal or negative mammogram/ultrasound and an unresolved clinical concern; personal history of breast cancer or current cancer diagnosis; palpable masses negative on mammogram or ultrasound; radiodense breast tissue; or high risk for breast cancer. In this population, BSGI had a reported sensitivity of 91%, specificity of 77%, PPV of 57%, and NPV of 96%. In 139 patients who had a suspicious lesion on mammography, BSGI imaging was negative in 21 cases, 13 of which were true negatives and 8 of which were false negatives.

Section Summary

The mix of indications in these studies makes it difficult to generalize the results or to determine whether the performance of BSGI varies by indication. Also, test accuracy may vary by indication and intended use. For example, high sensitivity is important if the objective is to identify multifocal or multicentric disease; high NPV is desirable if the goal is to reduce the number of women referred for biopsy.

Meta-Analysis of BSGI

Sun et al (2013) performed a systematic review and meta-analysis on the “clinical usefulness of [BSGI] as an adjunct modality to mammography for diagnosis of breast cancer.”(47) The authors included 19 studies in 5 separate analyses. Some of these studies were included in the evidence tables of the TEC Assessment, but others did not meet our inclusion criteria, eg, the study population comprised women with breast cancer. Random effects models were used when there was substantial heterogeneity.

The first analysis assessed the diagnostic performance of BSGI based on 8 studies. Heterogeneity was substantial (I²=53% for sensitivity, I²=91% for specificity). Pooled sensitivity was 95% (95% CI, 93 to 96), and pooled specificity was 80% (95% CI, 78 to 82). Studies with different indications for BSGI were pooled, and therefore results for test accuracy are difficult to interpret. Also, to assess quality of included
studies, the authors used a modified QUADAS instrument,(48) which was subsequently revised by the developers.(49) Overall, quality ratings were more favorable (ie, higher quality) than those in the TEC Assessment.

No studies that addressed health outcomes of interest were identified, nor is there sufficient indirect evidence to infer that the use of BSGI would yield improvements in health outcomes.

Summary

Evidence to date does not provide sufficient support for any of the uses discussed. The published literature on breast specific gamma imaging (BSGI), molecular breast imaging (MBI), and scintimammography with breast specific gamma camera is limited by a number of factors. Studies include populations that usually do not represent those encountered in clinical practice and that have mixed indications. There are  methodologic limitations of the available studies, which have been judged to have medium to high risk of bias, and they do not provide information about impacts on therapeutic efficacy. Limited evidence on diagnostic accuracy of BSGI indicates that the test has a relatively high sensitivity and specificity for detecting malignancy. However, evidence does not establish that BSGI improves outcomes when used as an adjunct to mammography for breast cancer screening. In available studies, Negative predictive value of BSGI has not been high enough to preclude biopsy in patients with inconclusive mammograms. The relatively high radiation dose also should be taken into account. In addition, evidence is insufficient to conclude that BSGI is better than magnetic resonance imaging for this purpose. Larger, higher-quality studies are required to determine whether BSGI has a useful role as an adjunct to mammography. For these reasons, BSGI is considered investigational.

Diagnostic accuracy of scintimammography for detecting axillary metastases is inadequate to preclude nodal dissection. Similarly, mobile gamma cameras for preoperative or intraoperative detection of sentinel lymph nodes have not shown improved diagnostic performance in comparison with standard gamma probes. Evidence comprises small studies with inconsistent results. For these reasons, detection of axillary metastases using scintimammography, BSGI, MBI, or preoperative or intraoperative mobile gamma cameras is considered investigational.

Clinical Trials

According to online site ClinicalTrials.gov, approximately 40 studies of BSGI, MBI, or portable gamma cameras are currently in progress, and many of them are being conducted at the Mayo Clinic. Active studies include:

  • MBI for patients with suspected DCIS (NCT00890994); N=200; estimated completion date of December 2015.
  • Low-dose Molecular Breast Imaging: Comparison of Breast Cancer Detection Rate at Initial Screening and Two-year Follow-up (NCT01723124); N=2000; estimated completion date of July 2016.
  • Use of Low-dose Molecular Breast Imaging for the Detection of Small Breast Lesions (Lowdoseprebx) (NCT01285440); N=150; estimated completion date of January 2014.
  • The Assessment of Molecular Breast Imaging (MBI) in Distinguishing Benign From Malignant Breast Disease (NCT01687790); N=60; estimated completion date of September 2014.
  • Intraoperative Gamma Camera for Breast Cancer Surgery (NCT00757302); N=110; estimated completion date of September 2014.
  • Internal Mammary Sentinel Lymph Node Biopsy in Early Breast Cancer Patients With Clinically Axillary Node–Negative (NCT01642511); N=4; estimated completion date of December 2013 (passed).

Practice Guidelines and Position Statements

The Society of Nuclear Medicine released a 2010 procedure guideline on breast scintigraphy using breast-specific gamma cameras.(2) The guideline lists potential indications and cites references for each indication but does not provide a systematic review of the literature, including assessment of study quality. The guideline is based on consensus, and most of it is devoted to procedures and specifications of the examination, documentation and recording, quality control, and radiation safety.

The American College of Obstetricians and Gynecologists’ practice bulletin on breast screening notes that scintimammography was considered but not recommended for routine screening.(50)

Appropriateness Criteria from the American College of Radiology rated BSGI a 1 or 2, indicating “usually not appropriate,” for breast cancer screening,(3) palpable breast masses,(4) and initial diagnostic workup of breast microcalcifications.(5)

References:

  1. O'Connor M, Rhodes D, Hruska C. Molecular breast imaging. Expert Rev Anticancer Ther 2009; 9(8):1073-80.
  2. Goldsmith SJ, Parsons W, Guiberteau MJ et al. SNM practice guideline for breast scintigraphy with breast-specific gamma-cameras 1.0. J Nucl Med Technol 2010; 38(4):219-24.
  3. American College of Radiology (ACR). Appropriateness criteria®: breast cancer screening, date of origin 2012. Available online at: http://www.acr.org/Quality-Safety/Appropriateness-Criteria. Last accessed April 2014.
  4. American College of Radiology (ACR). Appropriateness criteria®: palpable breast masses, last review date 2012. Available online at: http://www.acr.org/Quality-Safety/Appropriateness-Criteria. Last accessed April 2014.
  5. American College of Radiology (ACR). Appropriateness criteria®: breast microcalcifications - initial diagnostic workup, last review date 2009. Available online at: http://www.acr.org/Quality-Safety/Appropriateness-Criteria. Last accessed April 2014.
  6. Silverstein MJ, Recht A, Lagios MD et al. Image-detected breast cancer: state-of-the-art diagnosis and treatment. J Am Coll Surg 2009; 209(4):504-20.
  7. Lantheus Medical Imaging. Cardiolite® kit for the preparation of technetium Tc99m sestamibi for injection, July 2010. Available online at: http://www.cardiolite.com/healthcare-professionals/prescribing-info.asp. Last accessed April 2014.
  8. Hruska CB, O'Connor MK. Nuclear imaging of the breast: translating achievements in instrumentation into clinical use. Med Phys 2013; 40(5):050901.
  9. Schillaci O, Spanu A, Danieli R et al. Molecular breast imaging with gamma emitters. Q J Nucl Med Mol Imaging 2013; 57(4):340-51.
  10. GE Healthcare. Myoview™kit for the preparation of technetium Tc99m tetrofosmin for injection, May 2011. Available online at:
    http://www3.gehealthcare.com/en/Products/Categories/Nuclear_Imaging_Agents/Myoview. Last
    accessed April 2014.
  11. FDA. Gamma Medica™ Instruments 510(k) summary - January 18, 2000. Available online at: http://www.accessdata.fda.gov/scripts/cdrh/devicesatfda/index.cfm?db=pmn&id=K993813. Last accessed April 2014.
  12. Hruska CB, Boughey JC, Phillips SW et al. Scientific Impact Recognition Award: Molecular breast imaging: a review of the Mayo Clinic experience. Am J Surg 2008; 196(4):470-6.
  13. Hendrick RE. Radiation doses and cancer risks from breast imaging studies. Radiology 2010;257(1):246-53.
  14. Health risks from exposure to low levels of ionizing radiation: BEIR VII, Phase 2. Washington, DC: National Research Council of the National Academies Press; 2006.
  15. Hruska CB, Conners AL, Jones KN et al. Half-time Tc-99m sestamibi imaging with a direct conversion molecular breast imaging system. EJNMMI Res 2014; 4(1):5.
  16. Blue Cross and Blue Shield Association Technology Evaluation Center (TEC). Breast-specific gamma imaging (BSGI), molecular breast imaging (MBI), or scintimammography with breast-specific gamma camera. TEC Assessments 2013; Volume 28, Tab 2.
  17. Blue Cross and Blue Shield Association Technology Evaluation Center (TEC). Special report: screening asymptomatic women with dense breasts and normal mammograms for breast cancer. TEC Assessments 2013; Volume 28, Tab 15.
  18. Killelea BK, Gillego A, Kirstein LJ et al. George Peters Award: How does breast-specific gamma imaging affect the management of patients with newly diagnosed breast cancer? Am J Surg 2009; 198(4):470-4.
  19. Brem RF, Fishman M, Rapelyea JA. Detection of ductal carcinoma in situ with mammography, breast specific gamma imaging, and magnetic resonance imaging: a comparative study. Acad Radiol 2007; 14(8):945-50.
  20. Brem RF, Ioffe M, Rapelyea JA et al. Invasive lobular carcinoma: detection with mammography, sonography, MRI, and breast-specific gamma imaging. AJR Am J Roentgenol 2009; 192(2):379-83.
  21. Kim BS, Moon BI, Cha ES. A comparative study of breast-specific gamma imaging with the conventional imaging modality in breast cancer patients with dense breasts. Ann Nucl Med 2012; 26(10):823-9.
  22. Keto JL, Kirstein L, Sanchez DP et al. MRI versus breast-specific gamma imaging (BSGI) in newly diagnosed ductal cell carcinoma-in-situ: a prospective head-to-head trial. Ann Surg Oncol 2012;19(1):249-52.
  23. Rhodes DJ, Hruska CB, Phillips SW et al. Dedicated dual-head gamma imaging for breast cancer screening in women with mammographically dense breasts. Radiology 2011; 258(1):106-18.
  24. Brem RF, Rapelyea JA, Zisman G et al. Occult breast cancer: scintimammography with high-resolution breast-specific gamma camera in women at high risk for breast cancer. Radiology 2005; 237(1):274-80.
  25. Rechtman LR, Lenihan MJ, Lieberman JH et al. Breast-specific gamma imaging for the detection of breast cancer in dense versus nondense breasts. AJR Am J Roentgenol 2014; 202(2):293-8.
  26. Berrington de Gonzalez A, Berg CD, Visvanathan K et al. Estimated risk of radiation-induced breast cancer from mammographic screening for young BRCA mutation carriers. J Natl Cancer Inst 2009; 101(3):205-9.
  27. Ernestos B, Nikolaos P, Koulis G et al. Increased chromosomal radiosensitivity in women carrying BRCA1/BRCA2 mutations assessed with the G2 assay. Int J Radiat Oncol Biol Phys 2010;76(4):1199-205.
  28. Spanu A, Sanna D, Chessa F et al. The clinical impact of breast scintigraphy acquired with a breast specific gamma-camera (BSGC) in the diagnosis of breast cancer: incremental value versus mammography. Int J Oncol 2012; 41(2):483-9.
  29. Spanu A, Chessa F, Sanna D et al. Scintimammography with a high resolution dedicated breast camera in comparison with SPECT/CT in primary breast cancer detection. Q J Nucl Med Mol Imaging 2009; 53(3):271-80.
  30. Spanu A, Cottu P, Manca A et al. Scintimammography with dedicated breast camera in unifocal and multifocal/multicentric primary breast cancer detection: a comparative study with SPECT. Int J Oncol 2007; 31(2):369-77.
  31. Hruska CB, Phillips SW, Whaley DH et al. Molecular breast imaging: use of a dual-head dedicated gamma camera to detect small breast tumors. AJR Am J Roentgenol 2008; 191(6):1805-15.
  32. Spanu A, Chessa F, Meloni GB et al. The role of planar scintimammography with high-resolution dedicated breast camera in the diagnosis of primary breast cancer. Clin Nucl Med 2008;33(11):739-42.
  33. Brem RF, Petrovitch I, Rapelyea JA et al. Breast-specific gamma imaging with 99mTc-Sestamibi and magnetic resonance imaging in the diagnosis of breast cancer--a comparative study. Breast J 2007; 13(5):465-9.
  34. Tan H, Jiang L, Gu Y et al. Visual and semi-quantitative analyses of dual-phase breast-specific gamma imaging with Tc-99m-sestamibi in detecting primary breast cancer. Ann Nucl Med 2014;28(1):17-24.
  35. Kim JS, Lee SM, Cha ES. The diagnostic sensitivity of dynamic contrast-enhanced magnetic resonance imaging and breast-specific gamma imaging in women with calcified and non-calcified DCIS. Acta Radiol 2013.
  36. Taillefer R. The role of 99mTc-sestamibi and other conventional radiopharmaceuticals in breast cancer diagnosis. Semin Nucl Med 1999; 29(1):16-40.
  37. Schillaci O, Scopinaro F, Spanu A et al. Detection of axillary lymph node metastases in breast cancer with Tc-99m tetrofosmin scintigraphy. Int J Oncol 2002; 20(3):483-7.
  38. Spanu A, Dettori G, Nuvoli S et al. (99)mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis. Eur J Nucl Med 2001; 28(12):1781-94.
  39. Xu HB, Li L, Xu Q. Tc-99m sestamibi scintimammography for the diagnosis of breast cancer: meta-analysis and meta-regression. Nucl Med Commun 2011; 32(11):980-8.
  40. Bricou A, Duval MA, Charon Y et al. Mobile gamma cameras in breast cancer care - A review. Eur J Surg Oncol 2013.
  41. Lee HS, Ko BS, Ahn SH et al. Diagnostic performance of breast-specific gamma imaging in the assessment of residual tumor after neoadjuvant chemotherapy in breast cancer patients. Breast Cancer Res Treat 2014.
  42. Edwards C, Williams S, McSwain AP et al. Breast-specific gamma imaging influences surgical management in patients with breast cancer. Breast J 2013; 19(5):512-9.
  43. Brem RF, Floerke AC, Rapelyea JA et al. Breast-specific gamma imaging as an adjunct imaging modality for the diagnosis of breast cancer. Radiology 2008; 247(3):651-7.
  44. Park J, Lee A, Jung K et al. Diagnostic Performance of Breast-Specific Gamma Imaging (BSGI) for Breast Cancer: Usefulness of Dual-Phase Imaging with 99mTc-sestamibi. Nucl Med Mol Imaging 2013; 47(1):18-26.
  45. Park KS, Chung HW, Yoo YB et al. Complementary role of semiquantitative analysis of breast-specific gamma imaging in the diagnosis of breast cancer. AJR Am J Roentgenol 2014; 202(3):690-5.
  46. Weigert JM, Bertrand ML, Lanzkowsky L et al. Results of a multicenter patient registry to determine the clinical impact of breast-specific gamma imaging, a molecular breast imaging technique. AJR Am J Roentgenol 2012; 198(1):W69-75.
  47. Sun Y, Wei W, Yang HW et al. Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis. Eur J Nucl Med Mol Imaging 2013; 40(3):450-63.
  48. Whiting P, Rutjes AW, Reitsma JB et al. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003; 3:25.
  49. Whiting PF, Rutjes AW, Westwood ME et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011; 155(8):529-36.
  50. American College of Obstetricians and Gynecologists (ACOG). Breast cancer screening, ACOG Practice Bulletin no. 122, August 2011. Available online at:
    http://guidelines.gov/content.aspx?id=34275&search=scintimammography. Last accessed April 2014. 

Codes

Number

Description

CPT 

78800 

Radiopharmaceutical localization of tumor; limited area 

 

78801 

Radiopharmaceutical localization of tumor; multiple areas 

 

78803 

Radiopharmaceutical localization of tumor, tomographic (single positron emission computed tomography; SPECT) 

ICD-9 Diagnosis 

 

investigational for all diagnoses

ICD-9 Procedure 

92.19 

Radioisotope scan of other sites 

HCPCS 

A4641 

Radiopharmaceutical, diagnostic, not otherwise classified

  A4642 Indium In-111 satumomab pendetide, diagnostic, per study dose, up to 6 millicuries
 

A9500 

Technetium Tc-99m sestamibi, diagnostic, per study dose, up to 40 millicuries
   A9502 Technetium Tc-99m tetrofosmin, diagnostic, per study dose
   A9568 Technetium Tc-99m arcitumomab, diagnostic, per study dose, up to 45 millicuries
   A9572 Indium In-111 pentetreotide, diagnostic, per study dose, up to 6 millicuries

 

S8080

Scintimammography (radioimmunoscintigraphy of the breast), unilateral, including supply of radiopharmaceutical

ICD-10-CM (effective 10/1/15)   Investigational for all diagnoses
  C50.011 -C50.929 Malignant neoplasm of breast code range
  R92.0 - R92.8 Abnormal and inconclusive findings on diagnostic imaging of breast code range
  Z12.31 - Z12.39 Encounter for screening for malignant neoplasm of breast code range
ICD-10-PCS (effective 10/1/15)   ICD-10-PCS codes are only used for inpatient services. There is no specific ICD-10-PCS code for this imaging
  BH030ZZ, BH031ZZ, BH03YZZ, BH040ZZ, BH041ZZ, BH04YZZ, BH050ZZ, BH051ZZ, BH05YZZ, BH060ZZ, BH061ZZ, BH06YZZ Imaging, breast, plain radiography, mammary duct(s), contrast code range

Type of Service: 

Radiology 

Place of Service: 

Outpatient 

 


Index

 

Breast Specific Gamma Imaging
Miraluma®
Radionuclide Scanning, Breast
Scintimammography, Breast
 


Policy History

Date Action Reason
01/30/98 Add to Radiology section New policy
04/30/00 Replace policy Updated; expanded discussion on Rationale section, but policy statement unchanged
12/18/02 Replace policy Policy updated, references added. No change in policy statement
04/16/04 Replace policy Policy updated, reference number 5 added. No change in policy statement
11/9/04 Replace policy Benefit application statement modified due to deletion of code 78990 for provision of radiopharmaceuticals
03/15/05 Replace policy Policy updated with literature review; policy statement unchanged; reference numbers 8–10 added
03/7/06 Replace policy Policy updated with literature review; policy statement unchanged; additional discussion added regarding breast specific gamma cameras. References renumbered, reference numbers 8 and 9 added
04/25/06 Replace policy Discussion of Agency for Healthcare Research and Quality report and reference No. 15 added; policy statement unchanged
06/14/07 Replace policy Policy updated with literature review; policy statement unchanged. Reference numbers 15–17 added.
02/06/08 Replace policy- coding update only Code S8080 added to code table
07/10/08 Replace policy  Policy updated with literature review; reference numbers 18–22 added. Policy statement unchanged.
08/13/09 Replace policy Policy updated with literature search; references 24–32 added. No change to policy statements
10/08/10 Replace policy Policy updated with literature search; rationale and background extensively revised. References 1, 2, 12, 18, 20-23, 25, 27, 28 added. “Molecular breast imaging” added to policy statement as investigational; policy title changed to also add this term
5/10/12 Replace policy Policy updated with literature search. Reference 8,15,21,22 added. Policy statement unchanged.
5/22/14 Replace policy Policy updated with literature review on April 9, 2014; references 6-11, 15, 25, 34-35, 40-42, and 45 added; references 2-5 and 50 updated. Policy title changed to “Scintimammography and Gamma Imaging of the Breast and Axilla.” Rationale reorganized. New investigational policy statement for preoperative or intraoperative sentinel
lymph node detection using handheld or mounted mobile gamma cameras added. Other policy statement unchanged.