MP 7.03.11 Total Artificial Hearts and Implantable Ventricular Assist Devices

Medical Policy    
Section
Surgery 
Original Policy Date
11/30/96
Last Review Status/Date
Reviewed with literature search/2:2014
Issue
5:2014
  Return to Medical Policy Index

Disclaimer

Our medical policies are designed for informational purposes only and are not an authorization, or an explanation of benefits, or a contract.  Receipt of benefits is subject to satisfaction of all terms and conditions of the coverage.  Medical technology is constantly changing, and we reserve the right to review and update our policies periodically.


Description

A ventricular assist device (VAD) is a mechanical support attached to the native heart and vessels to augment cardiac output. The total artificial heart (TAH) replaces the native ventricles and is attached to the pulmonary artery and aorta; the native heart is typically removed. Both the VAD and TAH may be used as a bridge to heart transplantation or as destination therapy in those who are not candidates for transplantation. The VAD has also been used as a bridge to recovery in patients with reversible conditions affecting cardiac output.

Background

Heart failure may be the consequence of a number of differing etiologies, including ischemic heart disease, cardiomyopathy, congenital heart defects, or rejection of a heart transplant. The reduction of cardiac output is considered to be severe when systemic circulation cannot meet the body’s needs under minimal exertion. Heart transplantation improves quality of life and has survival rates at 1, 5, and 10 years of 88%, 74%, and 55%, respectively.(1) The supply of donor organs has leveled off, while candidates for transplants are increasing, compelling the development of mechanical devices.

Initial research into mechanical assistance for the heart focused on the TAH, a biventricular device which completely replaces the function of the diseased heart. An internal battery required frequent recharging from an external power source. Many systems utilize a percutaneous power line, but a transcutaneous power-transfer coil allows for a system without lines traversing the skin, possibly reducing the risk of infection. Because the heart must be removed, failure of the device is synonymous with cardiac death.

Ventricular assist devices. Implantable VADs are attached to the native heart, which may have enough residual activity to withstand a device failure in the short term. In reversible conditions of heart failure, the native heart may regain some function, and weaning and explanting of the mechanical support system after months of use has been described. VADs can be classified as internal or external, electrically or pneumatically powered, and pulsatile or continuous flow. Initial devices were pulsatile, mimicking the action of a beating heart. More recent devices may utilize a pump, which provides continuous flow. Continuous devices may move blood in rotary or axial flow.

Surgically implanted VADs represent a method of providing mechanical circulatory support for patients not expected to survive until a donor heart becomes available for transplant or for whom transplantation is otherwise contraindicated or unavailable. VADs are most commonly used to support the left ventricle, but right ventricular and biventricular devices may be used. The device is larger than most native hearts, and therefore the size of the patient is an important consideration: the pump may be implanted in the thorax or abdomen or remain external to the body. Inflow to the device is attached to the apex of the failed ventricle, while outflow is attached to the corresponding great artery (aorta for left ventricle, pulmonary artery for right ventricle). A small portion of ventricular wall is removed for insertion of the outflow tube; extensive cardiotomy affecting the ventricular wall may preclude VAD use.

Percutaneous ventricular assist devices. Devices in which most of the system’s components are external to the body are for short-term use (6 hours to 14 days) only, due to the increased risk of infection and need for careful, in-hospital monitoring. Some circulatory assist devices are placed percutaneously, ie, are not implanted. These may be referred to as percutaneous VADs (pVADs). The pVADs are placed through the femoral artery. Two different pVADs have been developed, the TandemHeart™ (Cardiac Assist™; Pittsburgh, PA), and the Impella® device (AbioMed™; Aachen, Germany). In the TandemHeart™ system, a catheter is introduced through the femoral artery and passed into the left atrium via transseptal puncture. Oxygenated blood is then pumped from the left atrium into the arterial system via the femoral artery. The Impella device is also introduced through a femoral artery catheter. In this device, a small pump is contained within the catheter that is placed into the left ventricle. Blood is pumped from the left ventricle, through the device, and into the ascending aorta. Adverse events associated with pVAD include access site complications such as bleeding, aneurysms, or leg ischemia. Cardiovascular complications can also occur, such as perforation, myocardial infarction (MI), stroke, and arrhythmias.

There are several situations in which pVAD may offer possible benefits: (1) cardiogenic shock that is refractory to medications and intra-aortic balloon pump (IABP), (2) cardiogenic shock, as an alternative to IABP, and (3) high-risk patients undergoing invasive cardiac procedures who need circulatory support.

Intra-aortic balloon pumps are outside the scope of this policy.

Regulatory Approval

Total Artificial Heart

In October 2004, device CardioWest™ Temporary Total Artificial Heart (SynCardia Systems Inc., Tucson, AZ) was approved by the U.S. Food and Drug Administration (FDA) through the premarket approval process (PMA) for use as a bridge to transplant in cardiac transplant-eligible candidates at risk of imminent death from biventricular failure. Also, the temporary CardioWest™ Total Artificial Heart (TAH-t) is intended for use inside the hospital. In April 2010, FDA approved a name-change to Syncardia Temporary Total Artificial Heart.

In September 2006, device AbioCor® Implantable Replacement Heart System (AbioMed Inc., Danvers MA) was approved by FDA through the Humanitarian Device Exemption (HDE) process for use in severe biventricular end-stage heart disease individuals who are not cardiac transplant candidates and who:

  • are younger than 75 years of age
  • require multiple inotropic support
  • are not treatable by LVAD destination therapy; and
  • are not weanable from biventricular support if on such support.

In addition to meeting other criteria, patients who are candidates for the AbioCor® TAH must undergo a screening process to determine if their chest volume is large enough to hold the device. The device is too large for approximately 90% of women and for many men. FDA is requiring the company to provide a comprehensive patient information package to patients and families. To further refine and improve the use of this artificial heart technology, AbioMed will conduct a postmarketing study of 25 additional patients. The postmarketing study was recommended by the Circulatory Systems Devices Panel, a part of FDA's Medical Devices Advisory Committee.

Ventricular Assist Devices

In December 1995, device Thoratec® Ventricular Assist Device System (Thoratec Corp., Pleasanton, CA) was approved by the FDA through the PMA for use as a bridge to transplantation in patients suffering from end-stage heart failure. The patient should meet all of the following criteria:

  1. candidate for cardiac transplantation,
  2. imminent risk of dying before donor heart procurement, and
  3. dependence on, or incomplete response to, continuous vasopressor support.

In May 1998, supplemental approval for the above device was given for the indication for postcardiotomy patients who are unable to be weaned from cardiopulmonary bypass. In June 2001, supplemental approval was given for a portable external driver to permit excursions within a 2-hour travel radius of the hospital in the company of a trained caregiver. In November 2003, supplemental approval was given to market the device as Thoratec® Paracorporeal VAD. In August 2004, supplemental approval was given to a modified device to be marketed as the Thoratec® Implantable VAD for the same indications. In January 2008, supplemental approval was given to delete Paracorporeal VAD use.

In February 2004, FDA approved the DeBakey VAD® Child under the HDE approval process. According to FDA, this device is indicated under HDE for both home and hospital use for children between the ages of 5 and 16 years who have end-stage ventricular failure requiring temporary mechanical blood circulation until a heart transplant is performed.

In April 2008, continuous flow device HeartMate® II LVAS (Thoratec, Pleasanton, CA) was approved by FDA through the PMA for use as a bridge to transplantation in cardiac transplant candidates at risk of imminent death from nonreversible left ventricular failure. The HeartMate II LVAS is intended for use both inside and outside the hospital. In January 2010, the device received the added indication as destination therapy for use in patients with New York Heart Association (NYHA) class IIIB or IV end-stage left ventricular failure who have received optimal medical therapy for at least 45 of the last 60 days and are not candidates for cardiac transplantation.

In October 2008, device Centrimag® Right Ventricular Assist Device (Levitronix, Zurich) was approved by FDA under the HDE to provide temporary circulatory support for up to 14 days for patients in cardiogenic shock due to acute right-sided heart failure.

In December 2011, the Berlin Heart EXCOR® Pediatric VAD was approved via HDE. The indications for this device are pediatric patients with severe isolated left ventricular or biventricular dysfunction who are candidates for cardiac transplant and require circulatory support.

In December 2012, FDA approved the Heartware® Ventricular Assist System (HeartWare Inc., Miami Lakes, FL) through the PMA. The device is approved as a bridge to cardiac transplantation in patients at risk for death, for patients at risk for death from refractory end-stage left ventricular heart failure.

Percutaneous Ventricular Assist Devices (circulatory assist devices)

The Impella® Recover LP 2.5 Percutaneous Cardiac Support System (Abiomed, Aachen, Germany) received FDA 510(k) approval in May 2008 for short-term (<6 hours) use in patients requiring circulatory support. The TandemHeart® (Cardiac Assist, Pittsburgh) received a similar 510(k) approval for short-term circulatory support in September 2005.

VAD Device

Manufacturer

Date of Initial Approval

Method of FDA Clearance

Indication

Thoratec® IVAD

Thoratec

August 2004

PMA Supplement

Bridge to transplant and postcardiotomy

DeBakey VAD® Child

MicroMed

April 2004

HDE

Bridge to transplant in children 5-16 years of age

HeartMate II®

Thoratec

April 2008

PMA

Bridge to transplant and destination

Centrimag®

Levitronix

October 2008

HDE

Postcardiotomy

Berlin Heart EXCOR® Pediatric VAD

Berlin

December 2011

HDE

Bridge to transplant

Heartware® Ventricular Assist System

HeartWare

December 2012

PMA

Bridge to transplant

pVAD Device

Manufacturer

Date of Initial Approval

Method of FDA Clearance

Indication

Impella®

Abiomed

May 2008

510(k)

Partial circulatory support using an extracorporeal bypass control unit for periods up to 6 h

TandemHeart®

Cardiac Assist

September 2005

510(k)

Temporary left ventricular bypass of ≤6 h

Several other devices are in clinical trials or awaiting FDA review.


Policy

Postcardiotomy Setting/Bridge to Recovery

Implantable ventricular assist devices with FDA approval or clearance may be considered medically necessary in the postcardiotomy setting in patients who are unable to be weaned off cardiopulmonary bypass.

Bridge to Transplantation

Implantable ventricular assist devices with FDA approval or clearance may be considered medically necessary as a bridge to heart transplantation for patients who are currently listed as heart transplantation candidates and not expected to survive until a donor heart can be obtained, or are undergoing evaluation to determine candidacy for heart transplantation.

Implantable ventricular assist devices with FDA approval or clearance, including HDEs, may be considered medically necessary as a bridge to heart transplantation in children 16 years old or younger who are currently listed as heart transplantation candidates and not expected to survive until a donor heart can be obtained, or are undergoing evaluation to determine candidacy for heart transplantation.

Total artificial hearts with FDA-approved devices may be considered medically necessary as a bridge to heart transplantation for patients with biventricular failure who have no other reasonable medical or surgical treatment options, who are ineligible for other univentricular or biventricular support devices, and are currently listed as heart transplantation candidates or are undergoing evaluation to determine candidacy for heart transplantation, and not expected to survive until a donor heart can be obtained.

Destination Therapy

Implantable ventricular assist devices with FDA approval or clearance may be considered medically necessary as destination therapy with end-stage heart failure patients who are ineligible for human heart transplant and who meet the following REMATCH Study criteria:

  • New York Heart Association (NYHA) class IV heart failure for 60 or more days, OR patients in NYHA class III/IV for 28 days, received 14 or more days’ support with intra-aortic balloon pump or dependent on IV inotropic agents, with 2 failed weaning attempts

In addition, patients must not be candidates for human heart transplant for 1 or more of the following reasons:

  • Age > 65 years; OR
  • Insulin-dependent diabetes mellitus with end-organ damage; OR
  • Chronic renal failure (serum creatinine > 2.5 mg/dL for ≥90 days; OR
  • Presence of other clinically significant condition

Other Indications

Other applications of implantable ventricular devices or total artificial hearts are considered investigational, including, but not limited to, the use of total artificial hearts as destination therapy. The use of non-FDA approved or cleared implantable ventricular assist devices or total artificial hearts is considered investigational.

Percutaneous ventricular assist devices (pVADs) are considered investigational for all indications.


Policy Guidelines

 

Only 2 VADs have approval from FDA for the pediatric population.The DeBakey VAD® Child device and the Berlin Heart EXCOR Pediatric VAD have FDA approval through the HDE process. The DeBakey VAD is indicated for use in children ages 5 to 16 years who are awaiting a heart transplant, ie, as a bridge to transplant while the Berlin Heart EXCOR VAD is indicated for children with severe isolated left ventricular or biventricular dysfunction who are candidates for cardiac transplant and require circulatory support.

In general, candidates for bridge-to-transplant implantable VADs are those who are considered appropriate heart transplant candidates but who are unlikely to survive the waiting period until a human heart donor is available. Some studies have included the following hemodynamic selection criteria: either a left atrial pressure of 20 mm Hg or a cardiac index of less than 2.0 L/min/m while receiving maximal medical support. Patients with VADs are classified by the United Network for Organ Sharing (UNOS) as Status I, that is, persons who are most ill and are considered the highest priority for transplant.

The median duration for time on the device is between 20 and 120 days.

Contraindications for bridge to transplant VADs and TAH include conditions that would generally exclude patients for heart transplant. Such conditions are chronic irreversible hepatic, renal, or respiratory failure; systemic infection; coagulation disorders, and inadequate psychosocial support. Due to potential problems with adequate function of the VAD or TAH, implantation is also contraindicated in patients with uncorrected valvular disease. See Policy No. 7.03.09 (heart transplantation) for further discussion of heart transplant candidacy.

In addition, individuals must have sufficient space in the thorax and/or abdominal cavity for the device. In the case of the CardioWest™ temporary Total Artificial Heart, this excludes individuals with body surface areas less than 1.7 m2 or who have a distance between the sternum and 10th anterior rib of less than 10 cm as measured by computed tomography (CT) scan.

Coding

Effective in 2013, the following category I codes were introduced:

33990: Insertion of ventricular assist device, percutaneous including radiological supervision and interpretation; arterial access only

33991: both arterial and venous access, with transseptal puncture

33992: Removal of percutaneous ventricular assist device at separate and distinct session from insertion

33993: Repositioning of percutaneous ventricular assist device with imaging guidance at separate and distinct session from insertion

CPT codes 0051T-0053T specifically describe artificial hearts.

Prior to 2013, CPT codes 0048T, 0050T specifically described the TandemHeart.


Benefit Application
BlueCard/National Account Issues

State or federal mandates (e.g., FEP) may dictate that all FDA-approved devices may not be considered investigational and, thus, these devices may be assessed only on the basis of their medical necessity.

Removal of the device prior to heart transplantation (CPT codes 33977-33978) is considered part of the global fee and incidental to the heart transplant.


Rationale 

 

Literature Review

This policy was created in 1996 and regularly updated with searches of the MEDLINE database. The most recent literature search was performed for the period from July 2012 through January 9, 2014. The literature review focuses on 3 types of devices: (1) left ventricular assist device (LVADs), (2) total artificial hearts (TAHs), and (3) percutaneous ventricular assist devices (pVADs). The literature review addresses short-term use of the devices as a bridge to recovery or transplantation. The LVADs and TAHs are also evaluated as longer-term destination therapy for patients who are not transplant candidates. Following is a summary of the key literature to date.

Left Ventricular Assist Devices

LVADs as Bridge to Recovery

Five studies of the Centrimag Right Ventricular Assist Device (RVADs) included between 12 and 32 patients, most of whom received biventricular devices.(2-4) Indications (and numbers of patients) in these 5 studies were: support for postcardiotomy cardiogenic shock (bridge to recovery, n=53), bridge to long- term device implantation (n=9), treatment of right heart failure in patients who previously received LVADs (n=15), bridge to later decision when neurologic status is clarified (n=16), and acute donor graft failure (n=6). The mean time on mechanical circulatory support ranged from 9.4 days to 46.9 days. The 30-day mortality rates were between 17% and 63%.The proportion of patients discharged from the hospital was between 30% and 83%. Major complications included bleeding requiring reoperation, sepsis, and stroke. No device failures were observed in these studies.

 

LVADs may have a role in bridging patients to recovery, particularly if there is reverse remodeling of the left ventricle. A number of relatively small, noncomparative studies have evaluated LVADs as bridge-to-recovery therapy. In a 2006 study, a series of 15 patients with severe heart failure due to nonischemic cardiomyopathy underwent implantation of LVADs, along with medical management designed to enhance myocardial recovery. Eleven of 15 patients had enough myocardial recovery to undergo LVAD explantation; 2 patients died after explantation. Among those who survived, the cumulate rate of freedom from recurring heart failure was 100% and 88.9%, respectively, at 1 and 4 years postexplantation. The same group subsequently reported results of their LVAD explantation protocol among patients with severe heart failure due to nonischemic cardiopathy who had nonpulsatile LVADs implanted.(5) They included 20 patients who received a combination of angiotensin converting enzyme ACE inhibitors, beta blockers, and adosterol antagonists followed by the β2-agonist clenbuterol. One patient was lost to follow-.up and died after 240 days of support. Of the remaining 19 patients, 12 (63.2%) were successfully explanted after a mean 286 days; estimated survival without heart failure recurrence was 83.3% at 1 and 3 years. In a prospective multicenter study to assess myocardial recovery in patients with LVAD implantation as a bridge to transplant, Maybaum et al evaluated 67 patients with heart failure who had undergone LVAD implantation for severe heart failure.(6) After 30 days, patients demonstrated significant improvements compared with pre-LVAD state in left ventricular ejection fraction (LVEF, 17.1% vs 34.12%, p<0.001), left ventricular end-diastolic diameter (7.1 cm vs 5.1 cm, p<0.001), and left ventricular mass (320 g vs 194 g, p<0.001). However, only 9% of patients demonstrated enough recovery to have their LVAD explanted.

Section Summary

The studies previously outlined indicate that a subset of patients who receive an LVAD as a bridge to transplant or as destination therapy demonstrate improvements in their cardiac function, sometimes to the point that they no longer require the LVAD. However, questions remain about defining and identifying the population most likely to experience cardiac recovery with LVAD placement. One clearly defined population in which the potential for myocardial recovery exists is in the postcardiotomy setting. The current evidence is insufficient to allow the identification of other heart failure patient populations who might benefit from the use of an LVAD as a specific bridge-to-recovery treatment strategy. Ongoing research studies are addressing this question, along with protocols for transitioning patients off LVAD use.

LVADs as Bridge to Transplant

A 1996 TEC Assessment concluded that LVADs can provide an effective bridge to transplantation.(7) Goldstein et al published a more recent review.(8) It should be recognized that LVADs do not change the number of patients undergoing heart transplantation due to the fixed number of donor hearts. However, the VAD will categorize its recipient as a high-priority heart transplant candidate.

Published studies continue to report that the use of a VAD does not compromise the success of a subsequent heart transplant and, in fact, may improve posttransplant survival, thus improving the use of donor hearts.(9-12) Currently available implantable LVADs consist of pulsatile devices that require stiff power vent lines that perforate the skin and implantable pump chambers, as well as nonpulsatile axial flow systems of smaller size and lower noise levels.(13)

In 5 reports published from 2007 to 2008, with samples ranging from 32 to 279 patients, most participants received the continuous-flow device as a bridge to transplantation.(14-18) Survival rates at 6 months were between 67% and 87%, and between 50% and 80% at 1 year. These rates are similar to those reported from a federal circulatory support device registry, the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS).(19) An additional report from INTERMACS comparing the HeartMate II with other LVAD devices for patients who received them with a bridge to transplantation indication reported that 91% and 80% of HeartMate II and other LVAD patients, respectively, reached transplant, cardiac recovery, or ongoing LVAD support by 6 months.(20) A study by Patel et al compared
HeartMate I and HeartMate II recipients at a single center, finding the same 1-year survival and similar rates of subsequent development of right heart failure.(17) Serious adverse events occurring after HeartMate II implantation include bleeding episodes requiring reoperation, stroke, infection, and device failure.

A systematic review published in 2011 examined the evidence on the effect of LVADs on posttransplant outcomes.(21) This review included 31 observational studies that compared outcomes of transplant in patients who did and did not have pretransplant LVAD. Survival at 1 year was more likely in patients who had LVAD treatment, but this benefit was confined to patients who received an intracorporeal device (relative risk [RR], 1.8; 95% confidence interval [CI], 1.53 to 2.13). For patients treated with an extracorporeal device, the likelihood of survival was not different from patients who were not treated with an LVAD (RR=1.08; 95% CI, 0.95 to 1.22). There was no difference in the risk of rejection between patients who did and did not receive LVAD treatment.

Additional studies published since the systematic review continue to report high success rates in bridging to transplant. In 2011, Strueber et al(22) published a case series of 50 patients awaiting heart transplantation treated with HeartWare® VAD. Patients were followed until transplantation, myocardial recovery, device explant, or death. The median duration of time on the LVAD was 322 days. Nine patients died; 3 from sepsis, 3 from multiple organ failure, and 3 from hemorrhagic stroke. At the end of follow-up, 20 patients had undergone transplant (40%), 4 had the pump explanted (8%), and the remaining 17 continued on pump support (34%). The most common complications were infection and bleeding. A total of 21 patients had infections (42%), and 5 patients had sepsis (10%). Bleeding complications occurred in
15 patients (30%), 10 of whom (20%) required surgery for bleeding.

In 2012, Aaronson et al reported results of a multicenter, prospective study of a newer generation LVAD, the HeartWare®, which is a smaller, continuous flow centrifugal device that is implanted in the pericardial space.(23) The study enrolled 140 patients who were awaiting heart transplantation who underwent HeartWare® implantation. A control group of 499 subjects comprised patients drawn from the INTERMACS database, which collects data on patients who receive FDA-approved durable mechanical
circulatory support devices. The study’s primary outcome was defined as survival on the originally implanted device, transplantation, or explantation for ventricular recovery at 180 days. Secondary outcomes were comparisons of survival between groups and functional, quality-of-life, and adverse event outcomes in the HeartWare® group. Success occurred in 90.7% of the HeartWare® group and 90.1% of controls (p<0.001, noninferiority with a 15% margin). Serious adverse events in the HeartWare® group included, most commonly, bleeding, infections, and perioperative right heart failure.

In 2013, Slaughter et al reported combined outcomes for patients included in the HeartWare® bridge-to-transplant study previously described and a continued-access protocol granted by FDA.(24) The study included 322 patients with heart failure, eligible for heart transplant, who received the HeartWare® (140 patients from the original study; 190 patients in the continue-access protocol who were monitored to outcome or had completed 180 days of follow-up at the time of this analysis). Survival at 60, 180, and 360 days was 97%, 91%, and 84%, respectively. The most common adverse events were respiratory dysfunction, arrhythmias, sepsis, and driveline exit site infections. Patients generally had improvements in quality-of-life measures.

Pediatric patients. There is 1 FDA-approved device, the EXCOR Pediatric VAD, via the humanitarian device exemption (HDE) process, available for use as a bridge to cardiac transplant in children. This HDE approval was based on data from children who were a part of the initial clinical studies of this device.(25) Publications have reported positive outcomes for children using VADs as a bridge to transplantation. Using the United Network for Organ Sharing (UNOS) database, Davies et al reported on use of VADs in pediatric patients undergoing heart transplantation.(26) Their analysis concluded that pediatric patients requiring a pretransplantation VAD have similar long-term survival to those not receiving mechanical circulatory support.

Following FDA approval, Fraser et al evaluated the EXCOR device among 48 children, aged 16 or younger with 2-ventricle circulation who had severe heart failure, despite optimized treatment and were listed for heart transplant.(27) Patients were divided into 2 groups based on body surface area; a historic control group of children receiving circulatory support with extracorporeal membrane oxygenation (ECMO) from the Extracorporeal Life Support Organization registry, matched in a 2:1 fashion with study participants based on propensity-score matching. For participants in cohort 1 (body surface area, <0.7 m2), the median survival time had not been reached at 174 days, while in the matched ECMO comparison group, the median survival was 13 days (p<0.001). For participants in cohort 2 (body surface area, 0.7 to <1.5 m2), the median survival was 144 days, compared with 10 days in the matched ECMO group (p<0.001). Rates of adverse events were high in both EXCOR device cohorts, including major bleeding (in 42% and 50% of cohort 1 and cohort 2, respectively), infection (in 63% and 50% of cohort 1 and cohort 2, respectively), and stroke (in 29% of both cohorts).

In 2013, Almond et al reported results from a prospective, multicenter registry to evaluate outcomes in children who received the Berlin Heart EXCOR device as a bridge to transplant.(28) This study included a broader patient population than the Fraser et al study. All patients were followed up from the time of EXCOR implantation until transplantation, death, or recovery. The study included 204 children, 67% of whom received the device under compassionate use. Survival at 12 months on EXCOR support was 75%, including 64% who survived to transplantation, 6% who recovered (device explanted and patient survived 30 days), and 5% alive with the device in place.

Section Summary

In adults, the evidence on the efficacy of LVADs as bridge to transplant consists of numerous uncontrolled trials and trials comparing different LVAD devices of patients who have no other treatment options. In children, the evidence consists of several uncontrolled trials and 1 trial with historical controls. These studies report that substantial numbers of patients survive to transplant in situations in which survival would not be otherwise expected. Despite the lack of high-quality controlled trials, this evidence is sufficient to determine that outcomes are improved in patients who have no other options for survival. The impact of pretransplant LVADs on survival from transplant is uncertain, with some studies reporting worse survival in patients receiving LVADs, but other studies reporting similar or improved survival.

LVADs as Destination Therapy

The policy regarding LVADs as destination therapy is based on a 2002 TEC Assessment(29) that offered the following observations and conclusions:

  • The available evidence comes from a single, well-designed and rigorously conducted randomized trial, known as the REMATCH study.(30) The study was a cooperative effort of Thoratec, Columbia University, and the National Institutes of Health.
  • The randomized trial found that patients with end stage heart failure who are not candidates for cardiac transplantation have significantly better survival on a VAD compared with treatment by optimal medical therapy. Median survival was improved by approximately 8.5 months. Serious adverse events were more common in the VAD group, but these appear to be outweighed by this group’s better outcomes on function; New York Heart Association (NYHA) class was significantly improved, as was quality of life among those living to 12 months.
  • VAD patients spend a greater relative proportion of time inside the hospital than medical management patients do, but the survival advantage would mean a longer absolute time outside the hospital.

Park et al published an extended 2-year follow-up of patients in the REMATCH trial, which found that survival and quality-of-life benefits were still apparent. In addition, this study and other case series suggest continuing improvement in outcomes related to ongoing improvements in the device and in patient management.(31,32) However, the durability of the HeartMate device used in the REMATCH trial is a concern; for example, at one participating institution, all 6 long-term survivors required device change-outs. Next generation devices consisting of smaller continuous flow devices are eagerly anticipated.

After publication of the REMATCH study results, Rogers et al published results from a prospective, nonrandomized clinical trial comparing LVAD as destination therapy with optimal medical therapy for patients with heart failure who were not candidates for heart transplant.(33) Fifty-five patients who had NYHA functional class IV symptoms and who failed weaning from inotropic support were offered a Novacor LVAD; 18 of these did not receive a device due to preference or device unavailability and acted as a control group. The LVAD-treated patients had superior survival rates at 6 months (46% vs 22%; p=0.03) and 12 months (27% vs 11%; p=0.02), along with fewer adverse events.

Section Summary

The main piece of evidence on the efficacy of LVADs as destination therapy in patients who are not transplant candidates is from a multicenter randomized controlled trial (RCT), the REMATCH study. This trial reported that the use of LVADs led to improvements in survival, quality of life, and functional status. This evidence is sufficient to establish that health outcomes are improved for this patient population.

Comparative Efficacy of Continuous Flow versus Pulsatile Flow Devices

In December 2009, Slaughter et al published data from an unblinded randomized multicenter trial comparing a continuous flow device with a pulsatile device.(34) Subjects were randomly assigned to continuous-flow or pulsatile-flow devices on a 2:1 block-randomization basis. The primary outcome measured was a composite end point of 2-year survival, free of disabling stroke or need for device replacement. Continuous-flow patients (n=134) reached the primary outcome at a rate of 46% (95% CI, 38 to 55) compared with pulsatile-flow patients’ (n=66) rate of 11% (95% CI, 3 to 18), which was a significant difference (p<0.001). Analysis of constituent factors indicated that a lower rate of devices needing replacement in the continuous-flow group had the largest effect on the composite end point; 2- year death rate also favored this device (58% vs 24%, respectively; p=0.008). Stroke and death (within 2 years of implantation) were similar in the 2 groups (stroke rate, 12%; death rate, 36%). Quality-of-life scores were also similar in the 2 groups. Although unblinded, this randomized trial adds to the evidence favoring continuous-flow devices.

Nativi et al(35) published a nonrandomized comparison of pulsatile versus continuous flow devices using data from the registry of the International Society for Heart and Lung Transplantation on 8557 patients undergoing transplant. Comparisons were made among patients receiving a pulsatile LVAD, a continuous flow LVAD, and no LVAD. Two time periods were used for analysis; the first was pre-2004, when nearly all LVADs were pulsatile devices, and post-2004 when continuous use devices began to be used in clinical care. Comparing the first time period to the second time period, there was a significantly greater risk of mortality in the first time period compared with the second time period (RR=1.30; 95% CI, 1.03 to 1.65; p=0.03). When analysis was confined to the second time period, there was no significant improvement in survival for the continuous group compared with the pulsatile group (RR=1.25; 95% CI,1.03 to 1.65; p=0.03).

Other nonrandomized studies that have compared outcomes from different types of LVADs have been smaller and/or focused on physiologic outcomes.(36-39) In some of these studies, the continuous flow devices exhibit greater improvement in physiologic measures, but none of these studies have reported significant differences between devices in clinical outcomes.

Section Summary

The evidence on the comparative efficacy of different devices consists of 1 RCT and several nonrandomized comparative studies. The RCT reported fairly large differences in a composite outcome measure favoring the continuous flow devices, with increases in revision and reoperation rates for the pulsatile device group being the largest factor driving the difference in outcomes. Other nonrandomized comparative studies, including 1 database study with large numbers of patients, have not reported
important differences between devices on clinical outcomes.

TAH
TAH as Bridge to Transplant

The FDA approval of the CardioWest TAH was based on the results of a nonrandomized, prospective study of 81 patients.(40) Patients had failed inotropic therapy and had biventricular failure and thus were not considered appropriate candidates for an LVAD. The rate of survival to transplant was 79%, which was considered comparable with the experience with LVAD in patients with left ventricular failure. The mean time from entry into the study until transplantation or death was 79.1 days.

Other case series have been reported on outcomes of the TAH as a bridge to transplant. For example, Copeland et al(41) reported on 101 patients treated with the SynCardia artificial heart as a bridge to transplant. All patients either met established criteria for mechanically assisted circulatory support, or were failing medical therapy on multiple inotropic drugs. The mean support time was 87 days, with a range of 1 to 441 days. Survival to transplant was 68.3% (69/101). Of the 32 deaths before transplant, 13 were due to multiple organ failure, 6 were due to pulmonary failure, and 4 were due to neurologic injury. Survival after transplant at 1, 5, and 10 years, respectively, was 76.8%, 60.5%, and 41.2%.

TAH as Destination Therapy

Data concerning the artificial heart are available from information concerning the FDA approval(42) and from a published article describing results for the first 7 patients.(43) FDA indicated that their decision was based on the company's laboratory and animal testing and on a small clinical study of 14 patients that was conducted by Abiomed. The patients had a 1-month survival prognosis of not more than 30%, were not eligible for cardiac transplants, and were felt to not benefit from VAD therapy. The study was reported to show that the device is safe and has likely benefit for people with severe heart failure whose death is imminent and for whom no alternative treatments are available. Of the 14 patients in the study, 12 survived surgery. Mean duration of support for the patients was 5.3 months. In some cases, the device extended survival by several months; survival was 17 months in 1 patient. Six patients were ambulatory; 1 patient was discharged home. Complications included postoperative bleeding and neurologic events. Device-related infection was "non-existent."

This device shows technologic progress, and these initial results are encouraging; however, a number of questions remain. These questions may be answered once the results of the 14-patient study are published, or data on a larger group of patients may be needed. One issue is to further analyze relevant patient outcomes (eg, complications, quality of life, survival). Therefore, based on current information, this device is considered investigational.

Section Summary

There is a smaller amount of evidence on the use of TAH as a bridge to transplantation, or as destination therapy, compared with the use of LVADs. The type of evidence on bridge to transplant is similar to that for LVADs, ie, case series reporting substantial survival rates in patients without other alternatives. Therefore, this evidence is sufficient to conclude that TAH improves outcomes for these patients similar to LVADs, and is a reasonable alternative for patients who require bridge to transplantation but who are ineligible for other types of support devices. There is insufficient evidence on the use of TAH as destination therapy to support conclusions.

pVADs
pVADs as an Alternative to Intra-Aortic Balloon Pump in Cardiogenic Shock

Three RCTs have been published that compare pVADs with intra-aortic balloon pumps (IABPs) for patients with cardiogenic shock,(44-46) along with a systematic review and meta-analysis of these 3 trials.(47) The meta-analysis was published in 2009 by Cheng et al. The 3 RCTs enrolled a total of 100 patients, 53 treated with a pVAD and 47 treated with an IABP. All 3 study populations included patients with acute myocardial infarction (MI) and cardiovascular shock; 1 of the trials(32) restricted this population to patients who were postrevascularization in the acute MI setting. The primary outcomes reported were 30-day mortality, hemodynamic measures of left ventricular (LV) pump function, and adverse events.

None of the 3 trials reported an improvement in mortality associated with pVAD use. The combined analysis estimated the relative risk for death in pVAD patients as 1.06 (95% CI, 0.68 to 1.66; p=0.80). All 3 trials reported an improvement in LV hemodynamics in the pVAD group. On combined analysis, there was a mean increase in cardiac index of 0.35 L/min/m2 for the pVAD group, an increase in mean arterial pressure of 12.8 mm Hg (95% CI, 3.6 to 22.0; p<0.001), and a decrease in pulmonary capillary wedge pressure of 5.3 mm Hg (95% CI, 1.2 to 9.4; p<0.05). Complications were more common in the pVAD group. On combined analysis, patients in the pVAD group had a significantly increased likelihood of bleeding events with a relative risk of 2.35 (95% CI, 1.40 to 3.93). Leg ischemia was also more common in the pVAD group, but this difference did not meet statistical significance (RR=2.59; 95% CI, 0.75 to 8.97; p=0.13).

Case series of patients treated with pVADs as an alternative to IABP in cardiogenic shock have been published, (48) and report high success rates as a bridge to alternative therapies. However, these studies do not add much to the evidence on efficacy that is reported from the RCTs.

pVADS as Bridge to Recovery in Cardiogenic Shock Refractory to IABP

Case series of patients with cardiogenic shock refractory to IABP who were treated with pVAD have also been published. In the largest series, Kar et al(49) treated 117 patients who had severe, refractory cardiogenic shock with the TandemHeart® System. Eighty patients had ischemic cardiomyopathy and 37 had nonischemic cardiomyopathy. There were significant improvements in all hemodynamic measures following LVAD placement. For example, cardiac index increased from 0.52±0.8 L/min/m2 to 3.0±0.9 L/min/m2 (p<0.001), and the systolic blood pressure increased from 75±15 mm Hg to 100±15 mm Hg (p<0.001). Complications were common post-LVAD implantation. Thirty-four patients had bleeding around the cannula site (29.1%), and 35 developed sepsis during the hospitalization (29.9%). Groin hematoma
occurred in 6 patients (5.1%); limb ischemia in 4 patients (3.4%); femoral artery dissection or perforation in 2 patients (1.7%); stroke in 8 patients (6.8%); coagulopathy in 13 patients (11.0%).

pVADs Ancillary Support in High-Risk Patients Undergoing Invasive Cardiovascular Procedures

The PROTECT trial intended to evaluate whether the Impella® 2.5 system improved outcomes for patients undergoing high-risk percutaneous coronary intervention (PCI) procedures. PROTECT I(50) was a feasibility study of 20 patients who had left main disease or last patent coronary conduit that required revascularization but who were not candidates for coronary artery bypass graft surgery. High-risk PCI was performed using the Impella® system for circulatory support. All of the procedures were completed successfully without any hemodynamic compromise during the procedures. There were 2 patient deaths within 30 days (10%), and 2 patients had a periprocedural MI (10%). An additional 2 patients had evidence of hemolysis, which was transient and resolved without sequelae.

The PROTECT II trial was planned as an RCT to compare the Impella® system with IABP in patients undergoing high-risk PCI procedures. Enrollment was planned for 654 patients from 50 clinical centers. The primary end point was the composite of 10 different complications occurring within 30 days of the procedure, with the authors hypothesizing a 10% absolute decrease in the complication rate for patients in the pVAD group. The trial was discontinued prematurely in late 2010 due to futility, after an interim analysis of the first 327 patients enrolled revealed that the primary end point could not be reached. At the point that the data safety and monitoring board stopped the study, 452 patients had been enrolled, 3 of whom withdrew consent and 1 who died. Results were published by O’Neill et al in 2012.(51) The study’s
primary analysis was intention to treat and included all 448 patients randomly assigned to the Impella® system (n=225) or IABP (n=223). The primary composite end point of major adverse effects at 30 days occurred in 35.1% of Impella® patients and in 40.1% of the IABP patients (p=0.277). There was no significant difference in the occurrence of in-hospital death, stroke, or MI between the Impella® patients and the IABP patients.

A few other case series have described pVAD use in high-risk patients undergoing an invasive cardiac procedure. Sjauw et al (52) performed a retrospective analysis of 144 consecutive patients undergoing high-risk PCI with pVAD support (Impella® system) from a European registry. End points included successful device function and incidence of adverse events at 30 days. The device was successfully implanted in all 144 patients. There was 1 periprocedural death and 8 deaths at 30 days for a mortality rate of 5.5%. Bleeding requiring transfusion or surgery occurred in 6.2% of patients, and vascular access site complications occurred in 4.0%. There was 1 stroke (0.7%) and no MIs were reported. Maini et al(53) performed a similar retrospective analysis of 175 patients undergoing high-risk PCI with pVAD support with the Impella® 2.5 circulatory support system. The primary safety end point was the incidence of major adverse cardiac events at 30 days. Secondary end points included device safety and efficacy and patient outcomes at 30 days and 12 months. Angiographic revascularization was successful in 99% of patients. At 30-day follow up, the major adverse cardiac event rate was 8%; survival was 96%, 91%, and 88% at 30 days, 6 months, and 12 months, respectively. Secondary safety end points occurring most frequently included acute renal dysfunction (2.8%), hypotension on support (3.4%), ventricular tachycardia, or cardiopulmonary resuscitation (2.8%); other vascular complications such as vessel dissection and arteriovenous fistula (3.4%), hematomas ipsi- or contralateral to the device insertion site (8.6%), infection (5.1%), and blood transfusion (9.7%).

Section Summary

pVADs have been tested in RCTs and uncontrolled studies of patients with cardiogenic shock and in patients undergoing high-risk cardiac interventions. The RCTs do not report a benefit for use of pVADs. In addition, both the RCTs and case series report high rates of adverse events that may outweigh any potential benefits. As a result, the evidence on pVADs does not support an improvement in health outcomes for patients with cardiogenic shock or in patients undergoing high-risk cardiac interventions.
Ongoing trials (all devices) A search of the website ClinicalTrials.gov identified the following ongoing trials that will include outcomes associated with mechanical circulatory support devices:

  • The Remission From Stage D Heart Failure (RESTAGE-HF) trial (NCT01774656). This is a noncomparative interventional study to determine the proportion of subjects who have enough improvement in ventricular function after undergoing a standardized LVAD plus pharmacologic recovery treatment and testing protocol to allow removal of the LVAD. Eligible subjects will have NYHA class IIIB/IV heart failure and be eligible for the HeartMate II implant as bridge to therapy or destination therapy. The HeartMate II device will be combined with a standardized protocol of medical therapy to enhance cardiac remodeling, including carvedilol, spironolactone, losartan,
    and digoxin. Enrollment is planned for 40 patients. The estimated study completion date is December 2017.
  • A Clinical Trial to Evaluate the HeartWare® Ventricular Assist System (ENDURANCE SUPPLEMENTAL TRIAL) (NCT01966458). This is a prospective, randomized, unblinded controlled trial to assess the incidence of stroke in patients with advanced heart failure receiving the HeartWare® ventricular assist system who received optimal blood pressure management and to compare stroke-free success among those receiving the HeartWare® device to those receiving other FDA-approved LVADs for destination therapy. Patients will be randomized to either an experimental group and receive the HeartWare® device, or an active comparator group. Enrollment is planned for 429. The estimated study completion date is October 2016.
  • A Prospective Study to Evaluate the Safety and Efficacy of the EVAHEART LVAS for Use as a Bridge-to-Transplant (NCT01187368). This is a prospective, noncomparative study to evaluate the safety and efficacy of the EVAHEART left ventricular assist system in patients with end-stage heart failure who are candidates for heart transplant. Enrollment is planned for 20 patients. The estimated study completion date is July 2016.
  • Evaluation of the Jarvik 2000 Left Ventricular Assist System With Post-Auricular Connector--Destination Therapy Study (NCT01627821). This is a prospective, randomized, unblinded controlled trial to compare the Jarvik 2000 Left Ventricular Assist system with Post-Auricular Connector to an active control group treated with the Thoratec HeartMate® II for destination therapy in patients with late-stage heart failure who are ineligible for heart transplant. Enrollment is planned for 350 patients. The estimated study completion date is December 2016.

Clinical Input Received Through Physician Specialty Societies and Academic Medical Centers

In response to requests, input was received through 2 physician specialty societies and 5 academic medical centers while this policy was under review in May 2014. While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

Vetting focused on the use of percutaneous ventricular assist devices in accordance with the American Heart Association/American College of Cardiology guidelines (2013) and the use of TAH as destination therapy. All of those providing input supported the use of implantable ventricular assist devices as destination therapy subject to the guidelines in the policy statements. Most of those providing input considered TAHs to be investigational for destination therapy; reviewers noted that there is limited clinical trial data to support the use of TAHs as destination therapy.

Most of those providing input considered pVADs to be investigational as a “bridge to recovery” or “bridge to decision” and for all other indications. Some reviewers noted that pVADs may improve patients’ hemodynamics better than other alternatives, such as an intra-aortic balloon pump, but are associated with more complications. Some reviewers noted that, despite a lack of evidence to indicate that pVADs improve overall outcomes, there may be cases when pVADs may be considered to support an
intervention or treatment for a life-threatening condition.

Summary

A ventricular assist device (VAD) is a mechanical support attached to the native heart and vessels to augment cardiac output. The total artificial heart (TAH) replaces the native ventricles and is attached to the pulmonary artery and aorta; the native heart is typically removed. There is a substantial body of evidence from clinical trials and observational studies supporting implantable VADs as a bridge to transplant in patients with end stage heart failure, possibly improving mortality, as well as quality of life. A well-designed clinical trial, with 2 years of follow-up data, demonstrates an advantage of implantable VADs as destination therapy for patients who are ineligible for heart transplant. Despite an increase in adverse events, both mortality and quality of life appear to be improved for these patients. Therefore, left ventricular assist devices (LVADs) may be considered medically necessary as a bridge to transplant and as destination therapy in patients who are not transplant candidates.

The evidence for TAH in these settings is less robust. However, given the limited evidence from case series and the lack of medical or surgical options for these patients, TAH is likely to improve outcomes for a carefully selected population with end stage biventricular heart failure awaiting transplant who are not appropriate candidates for an LVAD. TAH may be considered medically necessary for this purpose. There is insufficient evidence on the use of TAH as destination therapy, and TAH is considered investigational for this purpose.

The evidence on percutaneous VADs (pVADs) does not support that these devices improve health outcomes. Three RCTs of pVAD versus intra-aortic balloon pump (IABP) for patients in cardiogenic shock failed to demonstrate a mortality benefit and reported higher complications associated with pVAD use. A fourth RCT comparing pVAD with IABP as an adjunct to high-risk percutaneous coronary interventions was terminated early due to futility; analysis of enrolled subjects did not demonstrate significant improvements in the pVAD group. Case series of patients with cardiogenic shock refractory to IABP have reported improved hemodynamic parameters following pVAD placement. However, these uncontrolled series cannot determine if pVAD improves mortality, and high rates of complications are reported with pVAD use. Because of the lack of demonstrated benefits in clinical trials, and the high complication rates reported, the use of pVAD for all indications is considered investigational.

Practice Guidelines and Position Statements

The American College of Cardiology/American Heart Association (ACC/AHA) released guidelines for the management of heart failure in October 2013 that include recommendations related to the use of for mechanical circulatory support (MCS), including both durable and nondurable MCS devices.(54) The guidelines categorize pVADs and extracorporeal VADs as nondurable MCS devices. The following class IIA guidelines are made related to MCS devices:

  • MCS is beneficial in carefully selected patients with stage D heart failure with reduced ejection fraction (HFrEF) in whom definitive management (eg, cardiac transplantation) or cardiac recovery is anticipated or planned. (Level of Evidence: B)
  • Nondurable MCS, including the use of percutaneous and extracorporeal VADs, is reasonable as a “bridge to recovery” or “bridge to decision” for carefully selected patients with HFrEF with acute, profound hemodynamic compromise. (Level of Evidence; B)
  • Durable MCS is reasonable to prolong survival for carefully selected patients with stage D HFrEF. (Level of Evidence: B)

The AHA/ACC guidelines note:

“Although optimal patient selection for MCS remains an active area of investigation, general indications for referral for MCS therapy include patients with LVEF <25% and NYHA Class III–IV functional status despite GDMT, including, when indicated, CRT, with either high predicted 1- to 2- year mortality (eg, as suggested by markedly reduced peak oxygen consumption and clinical prognostic scores) or dependence on continuous parenteral inotropic support. Patient selection requires a multidisciplinary team of experienced advanced HF and transplantation cardiologists, cardiothoracic surgeons, nurses, and ideally, social workers and palliative care clinicians.”

In 2012, the American Heart Association published recommendations for the use of MCS.(55) These guidelines define nondurable MCS as intraballoon pumps, extracorporeal membrane oxygenation, extracorporeal VADs, and pVADs. The following recommendations were made regarding indications for use of MCS, including durable and nondurable devices:

  • MCS for bridge-to-transplant indication should be considered for transplant-eligible patients with end-stage heart failure who are failing optimal medical, surgical, and/or device therapies and at high risk of dying before receiving a heart transplantation. (Class I; Level of Evidence B).
  • Implantation of MCS in patients before the development of advanced heart failure is associated with better outcomes. Therefore, early referral of heart failure patients is reasonable. (Class IIa; Level of Evidence B).
  • MCS with a durable, implantable device for permanent therapy or destination therapy is beneficial for patients with advanced heart failure, high 1-year mortality resulting from heart failure, and the absence of other life-limiting organ dysfunction; who are failing medical, surgical, and/or device therapies; and who are ineligible for heart transplantation. (Class I; Level of Evidence B).
  • Elective rather than urgent implantation of destination therapy can be beneficial when performed after optimization of medical therapy in advanced heart failure patients who are failing medical, surgical, and/or device therapies. (Class IIa; Level of Evidence C).
    • Urgent nondurable MCS is reasonable in hemodynamically compromised heart failure patients with end-organ dysfunction and/or relative contraindications to heart
      transplantation/durable MCS that are expected to improve with time and restoration of an improved hemodynamic profile. (Class IIa; Level of Evidence C).
    • These patients should be referred to a center with expertise in the management of durable MCS and patients with advanced heart failure. (Class I; Level of Evidence C).
  • Patients who are ineligible for heart transplantation because of pulmonary hypertension related to heart failure alone should be considered for bridge to potential transplant eligibility with durable, long-term MCS. (Class IIa; Level of Evidence B).

The Heart Failure Society of America published guidelines in 2010 on surgical approaches to the treatment of heart failure.(56) The following recommendations were made regarding LVADs:

  • Patients awaiting heart transplantation who have become refractory to all means of medical circulatory support should be considered for a mechanical support device as a bridge to transplant. (Strength of Evidence = B)
  • Permanent mechanical assistance using an implantable assist device may be considered in highly selected patients with severe HF [heart failure] refractory to conventional therapy who are not candidates for heart transplantation, particularly those who cannot be weaned from intravenous inotropic support at an experienced HF center. (Strength of Evidence = B)
  • Patients with refractory HF and hemodynamic instability, and/or compromised end-organ function, with relative contraindications to cardiac transplantation or permanent mechanical circulatory assistance expected to improve with time or restoration of an improved hemodynamic profile should be considered for urgent mechanical circulatory support as a "bridge to decision." These patients should be referred to a center with expertise in the management of patients with advanced HF. (Strength of Evidence = C)

The European Society of Cardiology published guidelines in 2008 for the diagnosis and treatment of acute and chronic heart failure.(25) A focused update was published in 2010.(57) These guidelines included the following statements about LVADs:

  • Current indications for LVADs and artificial hearts include bridging to transplantation and managing patients with acute, severe myocarditis (Class IIa recommendation, level of evidence C). 
  • LVAD may be considered as destination therapy to reduce mortality in patients with severe heart failure who are ineligible for transplant. (Class IIb recommendation, level of evidence B).

Medicare National Coverage

Medicare has a national coverage determination for artificial hearts and related devices, including VADS.

The national coverage policy mandates coverage for VADs in the post-cardiotomy setting as long as the following conditions are met:

  • The VAD has approval from FDA for post-cardiotomy support.
  • The VAD is used according to the FDA-approved labeling instructions.

The national coverage policy also mandates coverage for VADs as a bridge-to-transplant as long as the following conditions are met:

  • The VAD has approval from FDA for the bridge-to-transplant indication.
  • The VAD is used according to the FDA-approved labeling instructions.
  • The patient is approved and listed as a candidate for heart transplantation by a Medicare-approved heart transplant center.
  • The implanting site, if different than the Medicare-approved transplant center, must receive written permission from the Medicare-approved heart transplant center under which the patient is listed prior to implantation of the VAD.

The national coverage policy mandates coverage for VADs as destination therapy as long as the following conditions are met:

  • The VAD has approval from FDA for the destination therapy indication.
  • Patient selection: VADs are covered for patients who have chronic end-stage heart failure (New York Heart Association class IV end-stage left ventricular failure) who are not candidates for heart transplantation, and meet all of the following conditions:
    • Have failed to respond to optimal medical management (including beta-blockers and ACE inhibitors if tolerated) for at least 45 of the last 60 days, or have been balloon pump-dependent for 7 days, or IV inotrope-dependent for 14 days; and,
    • Have a left ventricular ejection fraction (LVEF) <25%, and,
    • Have demonstrated functional limitation with a peak oxygen consumption of ≤14 mL/kg/min unless balloon pump- or inotrope-dependent or physically unable to perform the test.
  • Facility criteria: As of an October 30, 2013, decision memo on a National Coverage Analysis for VADs, the Centers for Medicare & Medicaid Services (CMS) concluded that the evidence is sufficient to conclude that VADs implanted in facilities that meet certain criteria improve health outcomes. Facilities currently credentialed by the Joint Commission for placement of VADs as DT [destination therapy] may continue as Medicare-approved facilities until October 30, 2014. At the conclusion of this transition period, these facilities must be in compliance with the following criteria as determined by a credentialing organization. As of the effective date, new facilities must meet the following criteria as a condition of coverage of this procedure:
    • Beneficiaries receiving VADs for DT must be managed by an explicitly identified cohesive, multidisciplinary team of medical professionals with the appropriate qualifications, training, and experience. The team embodies collaboration and dedication across medical specialties to offer optimal patient-centered care. Collectively, the team must ensure that patients and caregivers have the knowledge and support necessary to participate in shared decision making and to provide appropriate informed consent. The team members must be based at the facility and must include individuals with experience working with patients before and after placement of a VAD. The team must include, at a minimum, all of the following:
      • At least one physician with cardiothoracic surgery privileges and individual experience implanting at least 10 durable, intracorporeal, left ventricular VADs as BTT [bridge to transplant] or DT over the course of the previous 36 months with activity in the last year.
      • At least one cardiologist trained in advanced heart failure with clinical competence in medical and device-based management including VADs, and clinical competence in the management of patients before and after heart transplant.
      • A VAD program coordinator.
      • A social worker.
      • A palliative care specialist.
    • Facilities must be credentialed by an organization approved by CMS.

The national coverage policy mandates coverage for artificial hearts as bridge to transplant or destination therapy when performed under coverage with evidence development when a clinical study meets the criteria outlined in the Medicare policy and addresses one of the following questions:

  • Were there unique circumstances such as expertise available in a particular facility or an unusual combination of conditions in particular patients that affected their outcomes?
  • What will be the average time to device failure when the device is made available to larger numbers of patients?
  • Do results adequately give a reasonable indication of the full range of outcomes (both positive and negative) that might be expected from more widespread use?

Clinical trials that meet the above requirements will be listed on the CMS website (http://www.cms.gov/MedicareApprovedFacilitie/06_artificialhearts.asp).

References:

  1. 2008 OPTN/SRTR Annual Report 1998-2007. HHS/HRSA/HSB/DOT.
  2. Shuhaiber JH, Jenkins D, Berman M et al. The Papworth experience with the Levitronix CentriMag ventricular assist device. J Heart Lung Transplant 2008; 27(2):158-64.
  3. De Robertis F, Birks EJ, Rogers P et al. Clinical performance with the Levitronix Centrimag short-term ventricular assist device. J Heart Lung Transplant 2006; 25(2):181-6.
  4. De Robertis F, Rogers P, Amrani M et al. Bridge to decision using the Levitronix CentriMag short-term ventricular assist device. J Heart Lung Transplant 2008; 27(5):474-8.
  5. Birks EJ, George RS, Hedger M et al. Reversal of severe heart failure with a continuous-flow left ventricular assist device and pharmacological therapy: a prospective study. Circulation 2011;123(4):381-90.
  6. Maybaum S, Mancini D, Xydas S et al. Cardiac improvement during mechanical circulatory support: a prospective multicenter study of the LVAD Working Group. Circulation 2007; 115(19):2497-505.
  7. TEC Assessment Program 1996. Ventricular assist devices in bridging to heart transplantation. Volume 11, Tab 26.
  8. Goldstein DJ, Oz MC, Rose EA. Implantable left ventricular assist devices. N Engl J Med 1998;339(21):1522-33.
  9. Aaronson KD, Eppinger MJ, Dyke DB et al. Left ventricular assist device therapy improves utilization of donor hearts. J Am Coll Cardiol 2002; 39(8):1247-54.
  10. Frazier OH, Rose EA, McCarthy P et al. Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Ann Surg 1995; 222(3):327-36;
    discussion 36-8.
  11. Bank AJ, Mir SH, Nguyen DQ et al. Effects of left ventricular assist devices on outcomes in patients undergoing heart transplantation. Ann Thorac Surg 2000; 69(5):1369-74; discussion 75.
  12. Shuhaiber JH, Hur K, Gibbons R. The influence of preoperative use of ventricular assist devices on survival after heart transplantation: propensity score matched analysis. BMJ 2010; 340:c392.
  13. Wieselthaler GM, Schima H, Lassnigg AM et al. Lessons learned from the first clinical implants of the DeBakey ventricular assist device axial pump: a single center report. Ann Thorac Surg 2001; 71(3 Suppl):S139-43; discussion S44-6.
  14. Frazier OH, Gemmato C, Myers TJ et al. Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Tex Heart Inst J 2007; 34(3):275-81.
  15. John R, Kamdar F, Liao K et al. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. Ann Thorac Surg 2008; 86(4):1227-34; discussion 34-5.
  16. Miller LW, Pagani FD, Russell SD et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007; 357(9):885-96.
  17. Patel ND, Weiss ES, Schaffer J et al. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Ann Thorac Surg 2008; 86(3):832-40; discussion 32-40.
  18. Struber M, Sander K, Lahpor J et al. HeartMate II left ventricular assist device; early European experience. Eur J Cardiothorac Surg 2008; 34(2):289-94.
  19. Kirklin JK, Naftel DC, Stevenson LW et al. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transplant 2008; 27(10):1065-72.
  20. Starling RC, Naka Y, Boyle AJ et al. Results of the Post-U.S. Food and Drug Administration-Approval Study With a Continuous Flow Left Ventricular Assist Device as a Bridge to Heart Transplantation: A Prospective Study Using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). Journal of the American College of Cardiology 2011;57(19):1890-98.
  21. Alba AC, McDonald M, Rao V et al. The effect of ventricular assist devices on long-term post-transplant outcomes: a systematic review of observational studies. European journal of heart failure 2011; 13(7):785-95.
  22. Strueber M, O'Driscoll G, Jansz P et al. Multicenter evaluation of an intrapericardial left ventricular assist system. J Am Coll Cardiol 2011; 57(12):1375-82.
  23. Aaronson KD, Slaughter MS, Miller LW et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 2012; 125(25):3191-200.
  24. Slaughter MS, Pagani FD, McGee EC et al. HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant 2013; 32(7):675-83.
  25. Dickstein K, Cohen-Solal A, Filippatos G et al. ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: the Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM). European heart journal 2008; 29(19):2388-442.
  26. Davies RR, Russo MJ, Hong KN et al. The use of mechanical circulatory support as a bridge to transplantation in pediatric patients: an analysis of the United Network for Organ Sharing database. J Thorac Cardiovasc Surg 2008; 135(2):421-7, 27 e1.
  27. Fraser CD, Jr., Jaquiss RD, Rosenthal DN et al. Prospective trial of a pediatric ventricular assist device. N Engl J Med 2012; 367(6):532-41.
  28. Almond CS, Morales DL, Blackstone EH et al. Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 2013; 127(16):1702-11.
  29. TEC Assessment Program 2002. Left ventricular assist devices as destination therapy for end-stage heart failure. Volume 17, Tab 19.
  30. Rose EA, Gelijns AC, Moskowitz AJ et al. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 2001; 345(20):1435-43.
  31. Park SJ, Tector A, Piccioni W et al. Left ventricular assist devices as destination therapy: a new look at survival. J Thorac Cardiovasc Surg 2005; 129(1):9-17.
  32. Long JW, Kfoury AG, Slaughter MS et al. Long-term destination therapy with the HeartMate XVE left ventricular assist device: improved outcomes since the REMATCH study. Congest Heart Fail 2005; 11(3):133-8.
  33. Rogers JG, Butler J, Lansman SL et al. Chronic Mechanical Circulatory Support for Inotrope-Dependent Heart Failure Patients Who Are Not Transplant CandidatesResults of the INTrEPID Trial. Journal of the American College of Cardiology 2007; 50(8):741-47.
  34. Slaughter MS, Rogers JG, Milano CA et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009; 361(23):2241-51.
  35. Nativi JN, Drakos SG, Kucheryavaya AY et al. Changing outcomes in patients bridged to heart transplantation with continuous- versus pulsatile-flow ventricular assist devices: an analysis of the registry of the International Society for Heart and Lung Transplantation. J Heart Lung Transplant 2011; 30(8):854-61.
  36. Pruijsten RV, Lok SI, Kirkels HH et al. Functional and haemodynamic recovery after implantation of continuous-flow left ventricular assist devices in comparison with pulsatile left ventricular assist devices in patients with end-stage heart failure. European journal of heart failure 2012; 14(3):319-25.
  37. Lim KM, Constantino J, Gurev V et al. Comparison of the effects of continuous and pulsatile left ventricular-assist devices on ventricular unloading using a cardiac electromechanics model. J Physiol Sci 2012; 62(1):11-9.
  38. Kato TS, Chokshi A, Singh P et al. Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling. Circ Heart Fail 2011; 4(5):546-53.
  39. Ventura PA, Alharethi R, Budge D et al. Differential impact on post-transplant outcomes between pulsatile- and continuous-flow left ventricular assist devices. Clin Transplant 2011; 25(4):E390-5.
  40. Copeland JG, Smith RG, Arabia FA et al. Cardiac replacement with a total artificial heart as a bridge to transplantation. N Engl J Med 2004; 351(9):859-67.
  41. Copeland JG, Copeland H, Gustafson M et al. Experience with more than 100 total artificial heart implants. J Thorac Cardiovasc Surg 2012; 143(3):727-34.
  42. FDA information: AbioCor clinical results.
    http://www.accessdata.fda.gov/cdrh_docs/pdf4/H040006b.pdf. Last Accessed 8/10/2010. Last
    accessed 8/10/2010.
  43. Dowling RD, Gray LA, Jr., Etoch SW et al. Initial experience with the AbioCor implantable replacement heart system. J Thorac Cardiovasc Surg 2004; 127(1):131-41.
  44. Burkhoff D, Cohen H, Brunckhorst C et al. A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock. American heart journal 2006; 152(3):469 e1-8.
  45. Seyfarth M, Sibbing D, Bauer I et al. A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction. J Am Coll Cardiol 2008; 52(19):1584-8.
  46. Thiele H, Sick P, Boudriot E et al. Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock. Eur Heart J 2005; 26(13):1276-83.
  47. Cheng JM, den Uil CA, Hoeks SE et al. Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials. Eur Heart J 2009; 30(17):2102-8.
  48. Griffith BP, Anderson MB, Samuels LE et al. The RECOVER I: A multicenter prospective study of Impella 5.0/LD for postcardiotomy circulatory support. J Thorac Cardiovasc Surg 2012.
  49. Kar B, Gregoric ID, Basra SS et al. The percutaneous ventricular assist device in severe refractory cardiogenic shock. J Am Coll Cardiol 2011; 57(6):688-96.
  50. Dixon SR, Henriques JP, Mauri L et al. A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience. JACC. Cardiovascular interventions 2009; 2(2):91-6.
  51. O'Neill WW, Kleiman NS, Moses J et al. A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study. Circulation 2012; 126(14):1717-27.
  52. Sjauw KD, Konorza T, Erbel R et al. Supported high-risk percutaneous coronary intervention with the Impella 2.5 device the Europella registry. J Am Coll Cardiol 2009; 54(25):2430-4.
  53. Maini B, Naidu SS, Mulukutla S et al. Real-world use of the Impella 2.5 circulatory support system in complex high-risk percutaneous coronary intervention: the USpella Registry. Catheter Cardiovasc Interv 2012; 80(5):717-25.
  54. Yancy CW, Jessup M, Bozkurt B et al. 2013 ACCF/AHA Guideline for the Management of Heart FailureA Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Journal of the American College of Cardiology 2013; 62(16):e147-e239.
  55. Peura JL, Colvin-Adams M, Francis GS et al. Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association. Circulation 2012; 126(22):2648-67.
  56. Lindenfeld J, Albert NM, Boehmer JP et al. HFSA 2010 Comprehensive Heart Failure Practice Guideline. J Card Fail 2010; 16(6):e1-194.
  57. Dickstein K, Vardas PE, Auricchio A et al. 2010 Focused Update of ESC Guidelines on device therapy in heart failure: an update of the 2008 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure and the 2007 ESC guidelines for cardiac and resynchronization therapy. Developed with the special contribution of the Heart Failure Association and the European Heart Rhythm Association. Eur Heart J 2010; 31(21):2677-87.

Codes

Number

Description

CPT  33975  Implantation of ventricular assist device; extracorporeal, single ventricle 
   33976  Implantation of ventricular assist device; extracorporeal, biventricular 
   33977  Removal of ventricular assist device; extracorporeal, single ventricle 
   33978  Removal of ventricular assist device; extracorporeal, biventricular 
  33979 Insertion or ventricular assist device, implantable intracorporeal, single ventricle
  33980 Removal of ventricular assist device, implantable intracorporeal, single ventricle
  33990 Insertion of ventricular assist device, percutaneous including radiological supervision and interpretation; arterial access only
  33991 ;both arterial and venous access, with transseptal puncture
  33992 Removal of percutaneous ventricular assist device at separate and distinct session from insertion
  33993 Repositioning of percutaneous ventricular assist device with imaging guidance at separate and distinct session from insertion
  33999 Unlisted procedure, cardiac surgery
   0048T  Implantation of a ventricular assist device, extracorporeal, percutaneous, transseptal access, single or dual cannulation 
   0051T  Implantation of a total replacement heart system (artificial heart) with recipient cardiectomy 
   0052T  Replacement or repair of thoracic unit of a total replacement heart system (artificial heart) 
   0053T  Replacement or repair of implantable component or components of total replacement heart system (artificial heart) excluding thoracic unit 
ICD-9 Procedure  37.52 Implantation of total replacement heart system (artificial heart) 
  37.53 Replacement or repair of thoracic unit of total replacement heart system
  37.54 Replacement or repair of other implantable component of total replacement heart system
  37.63 Repair of heart assist system (includes replacement of parts of an existing VAD)
  37.66  Implant of an implantable, pulsatile heart-assist system (ventricular assist device) 
   37.68 Insertion of percutaneous external heart assist device (includes pVADs)
ICD-9 Diagnosis  398.91  Rheumatic heart failure (congestive) 
   402.01  Malignant hypertensive heart disease with congestive heart failure 
   402.11  Benign hypertensive heart disease with congestive heart failure 
   404.01  Malignant hypertensive heart and renal disease with congestive heart failure 
   404.03  Malignant hypertensive heart and renal disease with congestive heart failure and renal failure 
   404.11  Hypertensive heart and renal disease with congestive heart failure and renal failure 
   428.0  Congestive heart failure 
HCPCS Q0478 Power adapter for use with electric or electric/pneumatic ventricular assist device, vehicle type
  Q0479 Power module for use with electric or electric/pneumatic ventricular assist device, replacement only
  Q0480 Driver for use with pneumatic ventricular assist device, replacement only
   Q0481 Microprocessor control unit for use with electric ventricular assist device, replacement only
   Q0482 Microprocessor control unit for use with electric/pneumatic combination ventricular assist device, replacement only
   Q0483 Monitor/display module for use with electric ventricular assist device, replacement only
   Q0484 Monitor/display module for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0485 Monitor control cable for use with electric ventricular assist device, replacement only
   Q0486 Monitor control cable for use with electric/pneumatic ventricular assist device, replacement only
   Q0487 Leads (pneumatic/electrical) for use with any type electric/pneumatic ventricular assist device, replacement only
   Q0488 Power pack base for use with electric ventricular assist device, repalcement only
   Q0489 Power pack base for use with electric/pneumatic ventricular assist device, replacement only
   Q0490 Emergency power source for use with electric ventricular assist device, replacement only
   Q0491 Emergency power source for use with electric/pneumatic ventricular assist device, replacement only
   Q0492 Emergency power supply cable for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0493 Emergency power supply cable for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0494 Emergency hand pump for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0495 Battery/power pack charger for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0496 Battery for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0497 Battery clips for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0498 Holster for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0499 Belt/vest for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0500 Filters for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0501 Shower cover for use with electric or electric/pneumatic ventricular assist device, replacement only
   Q0502 Mobility cart for pneumatic ventricular assist device, replacement only
   Q0503 Battery for pneumatic ventricular assist device, replacement only, each
   Q0504 Power adapter for pneumatic ventricular assist device, replacement only, vehicle type
   Q0505  Miscellaneous supply or accessory for use with ventricular assist device  
   Q0506 Battery, lithium-ion, for use with electric or electric/phuematic ventricular assist device, replacement only
  Q0507 Miscellaneous supply or accessory for use with an external ventricular assist device
  Q0508 Miscellaneous supply or accessory for use with an implanted ventricular assist device
  Q0509 Miscellaneous supply or accessory for use with any implanted ventricular assist device for which payment was not made under Medicare Part A
ICD-10-CM (effective 10/1/15)  I09.81 Rheumatic heart failure  
  I11.0 Hypertensive heart disease with heart failure  
    I13.0 Hypertensive heart and chronic kidney disease with heart failure and stage 1 through stage 4 chronic kidney disease, or unspecified chronic kidney disease  
  I13.2 Hypertensive heart and chronic kidney disease with heart failure and with stage 5 chronic kidney disease, or end stage renal disease  
   I50.1-I50.9 Heart failure code range  
  I97.0 Postcardiotomy syndrome  
ICD-10-PCS (effective 10/1/15)  02RK0JZ + 02RL0JZ Total artificial heart is reported with a “cluster” of 2 codes for open replacement with synthetic substitute of the right and left ventricles  
  02HA0QZ, 02HA3QZ, 02HA4QZ Surgical, heart and great vessels, insertion, heart, implantable heart assist system; open, percutaneous and percutaneous endoscopic approach codes  
  02HA3RZ Surgical, heart and great vessels, insertion, heart, percutaneous, external heart assist system  
  02RK0JZ, 02RK4JZ, 02RL0JZ, 02RL4JZ Surgical, heart and great vessels, replacement, ventricle, synthetic substitute; codes for left and right, and open and percutaneous endoscopic approaches 
Type of Service  Surgery 
Place of Service  Inpatient 

Index

Artificial Heart
Assist Devices, Ventricular
Devices, Ventricular Assist, as a Bridge to Heart Transplantation
Total Artificial Heart
Ventricular Assist Devices as a Bridge to Heart Transplantation


Policy History

 

Date Action Reason
11/30/96 Add to Surgery section New policy
03/15/99 Replace policy Policy updated to include new FDA-approved devices
07/12/02 Replace policy Policy reviewed: Rationale section expanded, references added. Policy statement on use of VADs in patients who are not transplant candidates deleted; this topic will be addressed in a separate policy. Policy statement otherwise unchanged
12/18/02 Replace policy Policy statement revised to include 2002 TEC Assessment conclusions regarding VADs in patients who are not transplant candidates, i.e., “destination” therapy”
10/9/03 Replace policy Policy statement revised to limit medically necessary indications to FDA-approved devices. Policy statement added regarding investigational status of total artificial hearts. Additional 2003 category III CPT codes added
04/1/05 Replace policy Policy statement revised to indicate that a total artificial heart may be considered medically necessary as a bridge to transplant, based on FDA approval for that indication
06/27/05 Replace policy Policy statement for total artificial heart corrected (language removed that was erroneously left in the policy)
04/25/06 Replace policy Policy updated with literature review; policy statement unchanged. Reference numbers 10 and 11 added. HCPCS codes for replacement parts and accessories added to code table
10/10/06 Replace policy Policy updated with FDA approval of total artificial heart. Policy statements unchanged; total artificial hearts are investigational. Reference numbers 13, 14, 16, and 17 added. ICD-9 procedure code for total heart added.
04/09/08 Replace policy  Policy updated with literature search; no change in policy statements. Specific information added to Policy Guidelines about VADs that have FDA-approval for use in children. Reference numbers 15, 16, and 18 added.
08/13/09 Replace policy Policy updated with literature search; references 20 through 31 added. No change to policy statements
09/16/10 Replace policy Policy updated with literature search; References 1, 10, 19, 29 and 30 added. Extensive editing completed. Policy statements revised to address only implantable VADs and total artificial hearts.
09/01/11 Replace policy Policy updated with literature search. Percutaneous VADs added to policy statement and rationale. References 22, 30-39, 42, 43 added.
09/13/12 Replace policy Policy updated with literature search. References 18, 27-31, 33, 40, 47. Clause added to policy statement on TAH that says “…or are undergoing evaluation to determine candidacy for heart transplantation…”
11/8/12 replace policy - coding update only CPT codes updated
2/14/13 Replace policy Policy statement on children amended; age range changed from 5-16 to 0-16, reflecting the approval of the BERLIN heart EXCOR device for pediatric patients aged 0-16
3/14/13 Replace policy- correction only First paragraph in the Policy Guidelines revised to include the Berlin Heart EXCOR Pediatric VAD.
4/11/13 Replace policy- correction only Description section revised to remove statement that pVADs are outside the scope of this policy.
2/13/14 Replace policy Policy updated with literature review through January 9, 2014. Old references 51 and 55-56 removed; references 5-6, 20, 23-24, 27-28, 33, 52, 54, and 58-59 added.
5/22/14 Replace policy Policy updated with results of focused clinical vetting related to the use of pVADs and the total artificial heart as destination therapy. No change to policy statements.